Installation

i

nsert

v

enting

Refer to Figure 6 which shows a typical installation of this ap-
pliance into an existing solid-fuel fireplace.

WARNING: This appliance is equipped with a safety control sys-

tem designed to protect against improper venting of combustion

products. Operation of this heater when not connected to a prop-

erly installed and maintained venting system or tampering with

the blocked vent shut-off system can result in carbon monoxide

(CO) poisoning and possible death.

Insert must be vented to the outside in accordance with the current
edition of the National Fuel Gas Code ANSI-

Z223.1-latest edition,

also known as NFPA 54

. The insert must not be connected to a

chimney flue serving a separate solid fuel burning appliance.

This gas insert requires a 4” diameter B-vent or listed flex alu-

minum or stainless chimney liner extending the entire length

of the chimney to ensure proper operation. The vent should

terminate with a chimney cap or rain cap. Chimney should be

sealed around cap to prevent air and rain from entering chimney.

Adhere to vent manufacturer's instructions for installation and

vent termination.

A minimum flue height of 1 feet is recommended.

The insert must be installed so the draft hood is in the same

atmospheric pressure zone as the combustion air inlet to the

appliance.

f

lue

C

ollar

C

onneCtion

This insert has a detachable flue

collar to ease installation. To detach

flue collar lift removable vent (trivet)

from top of insert, unscrew draft tube

retaining screw (see Figure 5) and

slide draft tube and flue collar to the

rear. Attach flue collar (with 3 sheet

metal screws or a B-vent connector)

to vent pipe previously installed in

chimney. As the insert is pushed into

fireplace guide draft tube and flue col-

lar into guide brackets until draft tube

retaining screw can be reinstalled in

its original hole.

Chimney Cap

Storm Collar

Chimney - Use With

B-vent Chimney Or

Single Wall Gas Vent

Flex Chimney Liner

Listed To UL 1777 Or

ULC S65.

WARNING

Do not substitute the heat-rated flex liner (UL1777 or ULC

S65) for the exhaust with any other type liner or a fire

may result causing property damage, personal injury or

loss of life.

VENT KITS

Cat. #

Model

Description

H0906

VKBVI5

BVI, 4" Dia. x 5’ Length

H0907

VKBVI5

BVI, 4" Dia. x 5’ Length

Figure 7

Figure 6

Figure 5

Draft Tube

Retaining

Screw

The following vent liner kits are available from Lennox Hearth

Products (see Figure 7 and table below).