Lux Products SMART TEMP TX9100E User Manual
Page 6
6
3. Remove the body from the thermostat’s base by pressing
the thumb latch at the bottom center of the unit and
swinging the body away from the base.
NOTE:
If you are mounting the base to soft material like
plasterboard or if you are using the old mounting holes, the
screws may not hold. Drill a 3/16 in. (4.8mm) hole at each
screw, and insert the plastic anchors provided.
4. Hold the base against the wall. Route the wires through
the hole below the terminal block. Position the base for
best appearance (to hide any marks from an old
thermostat). Attach the base to the wall with the two
screws provided.
7. WIRING INFORMATION AND DIAGRAMS
CONNECTING THE WIRES
5. Wires must be trapped between the black
clamps and the brass terminals as shown
here.
6. Securely tighten all of the electrical terminal
screws, including any unused ones.
WIRING DIAGRAM NOTES:
(Important, please read all notes before connecting wires)
• If the information provided does not clearly represent your
system configuration, please refer to the “TECHNICAL
ASSISTANCE” section of this manual, and contact our
support department
before removing any of your existing
thermostat wiring.