3. -Stove door not closed tightly.

-Low draft pressure/draft stabilizer not closing (check pressure).

-Carbon deposits at oil entry (operate de-coking rod).

-Cold flue.

-Plugged flue.

-Wind conditions causing pressure to be out of limits.

-Faulty catalyst.


4. -Any problems in (3) above.

-Dirt, carbon, or residue in burner bottom or fuel connection at burner (operate de-

coker).

-Low-fire set too low on carburetor (adjust, see section 4).


5. -Carburetor out of adjustment (decrease high-fire screw).

-Cold flue.

-Draft stabilizer needs adjusting (allowing too much air into flue).

-Flame set too high (flame impinging on baffle too much).

-Faulty gasket (door rope, glass seal, or relief plate seal).

-Excessive residue in burner bottom.


6. -High wind, or unstable draft condition.

-Incorrect carburetor setting (increase low-fire screw).

-Draft stabilizer out of adjustment.

-Faulty carburetor.


7. -Abnormally high, gusty winds (If you live in a windy area, a second draft stabilizer

may need to be installed in the pipe as well to compensate).

-A wind-directional cap or vacuum cap may be helpful to prevent wind gusts and

down drafts from affecting pressure.


8. -No oil in tank.

-Valve in fuel supply line shut inadvertently.

-Fuel supply blocked (plugged filter, frozen water).

-Carburetor on/off lever tripped.


9. -Stove door having been open for a while and then shut (a roaring noise can occur for

a short period until draft stabilizes).

-Draft stabilizer unable to open enough to compensate with the high draft condition.

(adjust high-fire setting, see section 4)


10. -Carbon deposits (operate de-coking rod).

-Draft stabilizer stuck closed.

-Draft pressure too high.


11. -Carburetor adjusted too high, allowing too much flame impingement on stove top.

-Flue plugged or dirty.

-Dirty burner or plugged fuel inlet (operate de-coker/clean burner bottom)

-House pressure problem

-Draft stabilizer out of adjustment.

-Faulty or deteriorated catalyst.

-Blocked or inhibited air supply to stove (check outside air supply to stove or room).

-Faulty gasket (door rope, glass seal, relief plate seal, or burner gasket).