beautypg.com

Tools needed for installation, Parts supplied for installation, Electrical requirements – KITCHENAID 9752043 User Manual

Page 3: Electrical connection, Now start, A. b. c, D. 1, Warning, A. if connecting to a four-wire electrical system, B. where local codes permit

background image

Tools needed for
installation:

level

flat-blade
screwdriver or
5/16" nut
driver

pliers

Electrical
requirements

hammer

wrench

measuring tape
or ruler

Parts supplied for
installation:

If codes permit and a separate ground wire is
used, it is recommended that a qualified
electrician determine that the ground path is
adequate.

Do Not ground to a gas pipe.

Check with a qualified electrician if you are not
sure range is grounded.

Do Not have a fuse in the neutral or
ground circuit.

When a four-wire or three-wire, single-

phase, 120/240-volt, 60-Hz, AC-only,

electrical supply is available, a 50-ampere

maximum circuit protection is required, (or, if
specified on the model/serial rating plate, when a
four-wire or three-wire, single-phase 120/208-volt,
60 Hz, AC-only electrical supply is available, a 40-
ampere maximum circuit protection is required),
fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. The model/serial
rating plate is located on the oven frame behind the
drawer.

THE RANGE MUST BE CONNECTED
WITH COPPER WIRE ONLY.

Wire sizes and connections must conform
to the requirements of the National
Electrical Code, ANSI/NFPA 70 — latest

edition* or CSA Standard C22.1, Canadian

Electrical Code, Part 1 — latest edition** and all
local codes and ordinances for the kilowatt rating of
the range.

Phillips
screwdriver

3/8"
ratchet

hand or electric drill
wood floor: 1/8" drill bit

concrete/ceramic floor:
3/16" carbide-tipped
masonry drill bit

(Bracket must be
securely mounted to
sub-floor. Thickness
of flooring may
require longer
screws to anchor the
bracket to sub-floor.)

anti-tip
bracket

2 screws
(#10 x 1-1/2")

2 plastic
anchors

Panel B

Electrical

connection

This range must be connected to a grounded,
metallic, permanent wiring system, or a
ground connector should be connected to
the ground terminal or wire lead on the
range.

This range is manufactured with white (neutral)
power supply wire and a cabinet-connected
green ground wire twisted together.

Connect the range cable to the junction box
through a U.L.-listed conduit connector.
Complete electrical connection according to local
codes and ordinances.

A. If connecting to a four-wire
electrical system...

Do Not connect the cabinet-grounding
conductor to the neutral (white) junction box
wire:

Figure 1

1. Disconnect the power supply.
2.
Remove the terminal block cover.
3. Connect together 3 wires: green and white

appliance cable wires and the neutral (white)
wire in junction box.

4. Connect the two black wires together; then the

two red wires together. See Figure 2.

junction
box

red
wires

white
wires

bare or
green wire

cable from
power supply

black
wires

cable from
range

U.L.-listed
conduit
connector

B. Where local codes permit...

connecting the cabinet-grounding conductor
to the neutral (white) junction box wire:

C. Where local codes DO NOT
permit...

connecting the cabinet-grounding conductor
to the neutral (white) junction box wire.

Figure 3

Grounded Neutral

1. Disconnect the power supply.
2.
Separate the green and white appliance cable

wires.

3. Connect the white appliance cable wire to the

neutral (white) wire in the junction box.

4. Connect the two black wires together; then the

two red wires together. See Figure 3.

5. Connect the green or bare ground wire from

the appliance cable to a grounded wire in the
junction box.

junction
box

red
wires

white
wires

bare or
green
wires

cable from
power supply

black
wires

cable from
range

U.L.-listed
conduit
connector

Figure 2

Cable from
power supply

Junction
box

U.L.-listed
conduit
connector

Red
wires

White
wires

Black wires

cable from

range

Bare or
green
wires

1. Disconnect the power supply.
2.
Separate the green (or bare) and white

appliance cable wires.

3. Connect the white appliance cable wire to the

neutral (white) wire in the junction box.

4. Connect the two black wires together; then the

two red wires together. See Figure 1.

5. Connect the green appliance cablewire to the

green ground wire in the junction box.

Grounded Neutral

Now start...

With range in kitchen.

Put on safety glasses and gloves.
Remove shipping materials, tape and
protective film from range. Keep

cardboard bottom and shipping base under
range. Remove oven racks and parts package
from inside oven.

Take 4 cardboard
corners from the
carton. Stack one
cardboard corner
on top of another.
Repeat with the
other two
corners. Place
corners lengthwise
on the floor in back of range so corners will
support outer side edges of range as shown.

cardboard
corners

spacers

2.

Note: The metal chassis of the range MUST be
grounded in order for the control panel to work. If
the metal chassis of the range is not grounded, NO
keypads will operate. Check with a qualified
electrician if you are in doubt as to whether the
metal chassis of range is grounded.

safety
glasses

A.

B.

C.

Electrical Shock Hazard

Electrically ground range.

Failure to follow these instructions can
result in death, fire, or electrical shock.

WARNING

Electrical Shock Hazard

Turn power supply off before connecting
wires.

Use 8-gauge solid copper wire.

Electrically ground range.

Failure to follow these instructions can
result in death, fire, or electrical shock.

WARNING

This range should be connected
directly to the fused disconnect or circuit
breaker box through flexible, armored or

non-metallic sheathed, copper cable (with
ground wire). Locate the junction box to allow
two to three feet of slack in the line so that the
range can be moved if servicing is ever
necessary. Do Not cut the conduit.

A U.L.-listed conduit connector must be provided
at each end of the power supply cable (at the
range and at the junction box). Wires sizes
(COPPER WIRE ONLY) and connections must
conform with the rating of the range.

D.

1.

Copies of the standards listed may be obtained from:

*

National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269

**

Canadian Standard Association
178 Rexdale Boulevard
Rexdale (Toronto), Ontario M9W 1R3

gloves