4. Using the final measurement from Step 3, measure from the

floor up and mark a horizontal line on the wall where a wall
stud is located.

5. Position top of anti-tip bracket at line marked in Step 4 and

mark holes. Drill two

¹⁄₈" holes at the positions marked on the

wall. Use screws provided to fasten anti-tip bracket to wall.

Anti-tip bracket must be mounted securely to stud in wall
behind the range. Depending on thickness of the wall, longer
screws may be required. Longer screws are available from
your local hardware store.

Make Electrical Connection

This range must be connected to a grounded, metallic permanent
wiring system or a ground connector should be connected to the
ground terminal or wire lead on the range.

This range is manufactured with a cabinet-connected, green (or
bare) ground wire. Connect the range cable to the junction box
through the UL listed or CSA approved conduit connector.

1. Disconnect power.

2. Remove junction box cover if present.

3. Install a UL listed or CSA approved conduit connector to the

junction box.

4. Route the flexible cable conduit from the range to the junction

box using a UL listed or CSA approved conduit connector.

5. Tighten screws on conduit connector.

6. See “Electrical Connection Options Chart” to complete

installation for your type of electrical connection.

Electrical Connection Options Chart

4-Wire Cable from Home Power Supply

IMPORTANT: Use the 4-wire cable from home power supply
where local codes do not permit connecting to a 3-wire system.

1. Connect the 2 black wires (B) together using a UL listed wire

connector.

2. Connect the 2 red wires (C) together using a UL listed wire

connector.

3. Connect the 2 white wires (F) together using a UL listed wire

connector.

4. Connect the green (or bare) ground wire (H) from the range

cable to the green (or bare) ground wire (in the junction box)
using a UL listed wire connector.

5. Install junction box cover.

A. Horizontal line marked from Step 4.
B. Wall stud

C. Mounting screws
D. Anti-tip bracket

A. UL listed or CSA approved conduit connector

A

B

C

D

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge solid copper wire.

Electrically ground range.

Failure to follow these instructions can result in death,
fire, or electrical shock.

A

If your home has:

Go to Section:

4-wire

4-Wire Cable from Home
Power Supply

3-wire

3-Wire Cable from Home
Power Supply

A. Cable from home power supply
B. Black wires

C. Red wires
D. 4-wire flexible cable from range

E. Junction box

F. White wires

G. UL listed wire connectors
H. Green (or bare) ground

wires

I. UL listed or CSA approved

conduit connector

½"

(1.3 cm)

½"

(1.3 cm)

A
B

C

D

E

F

G

H

I