Dimensions and specifications – Kenmore 625.347001 User Manual
Page 15
15
-- DIMENSIONS and SPECIFICATIONS --
16”
16”
9”dia.
15”
STORAGE
TANK
Metric
Supply water pressure limits . . . . . . . . . . . . . . . . . . . . . . . .
40 --- 125 psi
280 --- 860 kPa
Supply water temperature limits . . . . . . . . . . . . . . . . . . . . .
40 --- 100 ° F
5 --- 40° C
Maximum total dissolved solids (TDS) . . . . . . . . . . . . . . .
2000 ppm
Maximum water hardness @ 6.9 pH . . . . . . . . . . . . . . . . .
10 gpg
Maximum iron, manganese, hydrogen sulfide . . . . . . . . .
0
Chlorine in water supply (max. ppm) . . . . . . . . . . . . . . . .
2.0
Supply water pH limits (pH) . . . . . . . . . . . . . . . . . . . . . . . .
4 --- 10
Product (quality) water, 24 hours ¬ . . . . . . . . . . . . . . . . .
6 gal.
22.7 liters
Waste water per gallon of product water ¬ . . . . . . . . . . .
5 gal.
18.9 liters
Percent rejection of TDS, minimum (new membrane) ¬
90 --- 95
Storage tank capacity (max.) . . . . . . . . . . . . . . . . . . . . . . .
2.3 gal.
8.7 liters
Automatic shutoff control . . . . . . . . . . . . . . . . . . . . . . . . . . .
yes
¬
feed water supply at 50 psi, 77° F, and 750 TDS --- Quality water production, amount of waste
water and percent rejection all vary with changes in pressure, temperature and total dissolved solids.