Product specifications – Kenmore The Economizer(TM) 6 Compact Electric 153.31604 User Manual
Page 5

5
PRODUCT SPECIFICATIONS
MAXIMUM FUSE
RECOVERY RATE
MINIMUM
OR CIRCUIT
MODEL
IN GALLONS
GALS.PER HOUR
WIRE SIZE*
BREAKER
NUMBER
(LITERS)
DIA.
HEIGHT
@90
0
F Rise
120 Volt 240 Volt
(GAUGE)
SIZE (AMPS)
153.316040
6 (22.7)
14.250” (362) 15.375” (391)
7.5
1650
----
12
20
153.316050
10 (37.8)
16” (406) 18.25” (464)
7.5
1650
----
12
20
153.316060
19 (71.9)
18” (457)
24.9” (632)
7.5
1650
----
12
20
153.316070
19.9 (75.3)
16” (406) 31.62” (803)
7.5
1650
----
12
20
153.316331
30 (113.6)
22” (559)
30” (762)
7.5
1650
----
12
20
153.326060
19 (71.9)
18” (457)
24.9” (632)
9.1
----
2000
14
15
153.326070
19.9 (75.3)
16” (406) 31.62” (803)
9.1
----
2000
14
15
153.326331
30 (113.6)
22” (559)
30” (762)
9.1
----
2000
14
15
* Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical code.
Some compact models have labeled optional plumbing connections see below.
MODEL
NUMBER
STANDARD
SIDE COLD INLET
STANDARD
SIDE HOT INLET
STANDARD
SIDE T&P
MODEL HAS OPTIONAL
TOP COLD INLET
MODEL HAS OPTIONAL
TOP HOT OUTLET OR T&P
5.600
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
5.6050
YES
YES
YES
NO
YES, PLUGGED
5.6060
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
5.6070
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
5.6
YES
YES
YES
NO
NO
153.326060
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
153.326070
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
153.326331
YES
YES
YES
NO
NO
DIMENSIONS
IN INCHES (mm)
TANK
CAPACITY
ELEMENT
WATTAGE
HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF
A LICENSED TRADESMAN IN THE FIELD INVOLVED.
PLUMBING AND ELECTRICAL WORK ARE REQUIRED.
Examine the location to ensure the water heater complies with the
“Facts to Consider About the Location” section in this manual.
5. For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during
an earthquake. See instructions for correct installation
procedures. Instructions may be obtained from California
Office of the State Architect, 400 P Street, Sacramento,
CA 95814.
6. Massachusetts Code requires this water heater to be
installed in accordance with Massachusetts 248-CMR
2.00: State Plumbing Code and 248-CMR 5.00.