beautypg.com

Venting – Kenmore 153.338073 User Manual

Page 15

background image

15

Venting

VENT DAMPERS - Any vent damper, whether it is operated
thermally or otherwise must be removed if its use inhibits proper
drafting of the water heater.

Thermally Operated Vent Dampers: This gas-fired water
heater has a thermal efficiency at or above 80% which may
produce a relatively low flue gas temperature. Such
temperatures may not be high enough to properly open thermally
operated vent dampers. This would cause spillage of the flue
gases and may cause carbon monoxide poisoning.

Vent dampers must bear evidence of certification as complying
with the current edition of the American National Standard
ANSI Z21.66/CGA 6.14, cover electrically and mechanically
actuated vent dampers). Before installation of any vent damper,
consult your local Sears Service Center or the local gas supplier
for further information.

To insure proper venting of this gas-fired water heater, the
correct vent pipe diameter must be utilized. Any additions
or deletions of other gas appliances on a common vent with
this water heater may adversely affect the operation of the
water heater. Consult your gas supplier if any such changes
are planned.

For proper venting in certain installations, a larger diameter vent
pipe may be necessary. Consult your local Sears Service Center
or gas supplier to aid you in determining the proper venting for
your water heater from the vent tables in the current edition of
the National Fuel Gas Code ANSI Z223.1/NFPA 54.

Periodically check the venting system for signs of obstruction or
deterioration and replace if needed.

The combustion and ventilation air flow must not be obstructed.

The water heater with draft hood installed must be connected to
a chimney or listed vent pipe system, which terminates to the
outdoors. Never operate the water heater unless it is vented to
the outdoors and has adequate air supply to avoid risks of
improper operation, explosion or asphyxiation.

For proper draft hood attachment, the draft hood legs may
be angled slightly inward.

Place the draft hood legs in the receiving holes on the top of
the water heater. The legs will snap in the holes to give a
tight fit. Secure the legs of the draft hood with the supplied
draft hood brackets.

Place the vent pipe over the draft hood. With the vent pipe in
position, drill a small hole through both the vent pipe and
draft hood. Secure them together with a sheet metal screw,
see Figure 17.

FIGURE 17.

Obstructed or deteriorated vent systems may present serious
health risk or asphyxiation.

The vent pipe from the water heater must be no less than the
diameter of the draft hood outlet on the water heater and must
slope upward at least 1/4 inch per linear foot (21 mm per meter),
see Figure 18.

FIGURE 18.

All vent gases must be completely vented to the outdoors of the
structure (dwelling). Install only the draft hood provided with the
new water heater and no other draft hood.

Vent pipes must be secured at each joint with sheet metal
screws.

There must be a minimum of 6 inches (153 mm) clearance
between single wall vent pipe and any combustible material.
Fill and seal any clearance between single wall vent pipe and
combustible material with mortar mix, cement, or other
noncombustible substance. For other than single wall, follow
vent pipe manufacturer’s clearance specifications. To insure a
tight fit of the vent pipe in a brick chimney, seal around the vent
pipe with mortar mix cement.

Failure to have required clearances between vent piping and
combustible material will result in a fire hazard.

Be sure vent pipe is properly connected to prevent escape of
dangerous flue gases which could cause deadly asphyxiation.

This manual is related to the following products: