1. Operating Controls

B. System Operation

B1

3 8 6 7 1 4 5 2 9

1

Emergency-STOP master switch
Q1

Switches the system ON and OFF; also serves as
Emergency-STOP switch.

2

Unlock button with operational
indicator light

starts the availability time of the pump by the press of the
button serves for resetting after malfunctions
is alight when the pump is running and during the
availability time

3

Pressure gauge

Indicates the pressure downstream of the pump; also
serves as function control.

4

Indicator lamp – Motor Fault

Illuminates when the motor protection switch has tripped,
switching off the motor (motor fault).

5

Indicator lamp – General Fault

is illuminated for:
– motor malfunction
– drop in system pressure (at high-pressure outlet)
– water temperature too high
– motor temperature or oil temperature too high-
insufficient water
– admission pressure of hot-water pump too low.

6

Elapsed-hour meter

Counts the total pump operating hours.

7

Warning Label

Danger!
Danger of Death by electrical shock!
Control cabinet may be opened by trained personnel only

8

Control cabinet closure

Used for opening the control cabinet
May be opened by trained personnel only

9

Fault indication on the printed
circuit board

indicates following malfunctions:
1 insufficient water, water temperature too high
2 motor or oil temperature too high
3 admission pressure of hot-water pump too low
4 drop in pressure at high-pressure outlet