F. Trouble Shooting

F3

Motor fault lights up

Motor protection switch
Q1 or Q2 has triggered
owing to overcurrent or
drop-out of one phase
of power supply
system

Check voltage of the three
phases

Customer
Service/
Electrician

Motor protection switch
falsely set

Set in accordance with
circuit diagram

Customer
Service/
Electrician

Pressure at pump
outlet too high

Check pressure, adjust as
necessary

Customer
Service

Available time is less than
6 hours

Site high-pressure
network is leaky

Seal it off

Operator

Pressure switch
defective

Replace

Kundendienst

System does not start up
when unlock button is
pressed, no indicator light
illuminates

Site power supply
interrupted

switch on

Operator

Emergency-STOP
master switch off

switch on

Operator

Motor protection switch
for control system and
precompression pump
has been triggered

check

Customer
Service /
Electrician

Control-circuit fuse on
transformer defective

replace, check cause

Customer
Service /
Electrician

Printed circuit board
defective, green LED
does not blink

replace, check

Customer
Service

EPROM loose

install again, check cause

Customer
Service /
Electrician

This manual is related to the following products: