Under the cabinet installation, Safety warning – Kobe Range Hoods RA3836SQD User Manual
Page 7
5
UNDER THE CABINET INSTALLATION
SAFETY WARNING
HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF
REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING.
NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD
MAY OCCUR.
Preparation before Installation
- Temporarily wire the hood to test for proper operation before installing.
- Peel protective film off the hood (if any).
- For installing under the cabinet with recessed bottom, attach 4-inch wide wood filler
strips (not included) on each side. Refer to Figure 1.
- Measure and create access opening for electrical wires under the cabinet.
Hood Installation
CAUTION: If required to move the cooking range to install the hood, turn off the power on an
electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS
RANGE.
1.
Puncture the knockout holes. Refer to Figure 2.
Figure 1 Figure 2
2.
Unscrew the six screws on the bottom casing. Remove the bottom casing as shown in
Figure 3. If necessary, arrange the electrical wire to run through the 1” diameter hole on
the hood.
3.
Use calculation on Table 1 and measurements on page 14 as references. Center the hood
in place beneath the cabinet and flush with the front of the cabinet. Refer to Figure 4.