Troubleshooting (cont.)

Symptoms

Probable
Causes

Recommended Action

D.

There is

water

leakage on

electrical

components

or

connectors.

D.

Remove the cover and check

for corrosion on the

connections between the

battery to solenoid and the

battery holder to the sensor. If

possible, clean the terminals. If

unable to repair the connection,

order a new sensor assembly,

battery holder, or solenoid

assembly, as required. Inspect

the gasket between the valve

body and spout hose for cuts,

debris, etc. If the gasket is

damaged, order a new gasket.

The origin of the leak must be

investigated and repaired.

E.

The

battery life

has

expired.

E.

Remove the cover and replace

the battery. The faucet requires

a standard 2CR5 6 V lithium

battery. This item is not

available from Kohler Co., but

can be purchased at retail

stores.

F.

Sensor

eyes are

dirty.

F.

Wipe the sensor eyes with a

damp soft cloth. Wipe dry with

a dry soft cloth.

G.

Supply

pressure is

low.

G.

Verify that the water supply is

turned on and that pressure is

at least 20 psi (137 kPa).

H.

Incorrect

installation.

H.

Verify that the faucet is

mounted flat to the deck

surface and that the sensor eyes

are aligned to the user area.

I.

The filters

are

plugged.

I.

Refer to the

″Service the Filters″

section of the Homeowners

Guide.

J.

The

aerator is

plugged.

J.

Remove the aerator and clean.

For calcium/mineral deposits,

soak the plastic insert in a 50:50

mix of water and vinegar. Soak

only the plastic insert.

K.

Sensor

eyes are

scratched.

K.

Replace the sensor assembly.

Kohler Co.