Specifications – Kenmore 300 Series User Manual
Page 33

33
Specifications
FIG. 45
Questions? Call The Kenmore Water Line 1-800-426-9345
Intermittent flow rate does not represent the maximum service flow rate used for determining the soften-
ers rated capacity and efficiency. Continuous operation at flow rates greater than the service flow rate
may affect capacity and efficiency performance.
These systems conform to NSF / ANSI 44 for the specific performance claims as verified and substantiat-
ed by test data.
The efficiency rating is only valid at the minimum stated salt dosage. These softeners were efficiency
rated acocording to NSF / ANSI Standard 44.
OTHER SPECIFICATIONS
MODEL 38306
MODEL 39306
Type of ion exchange material
high capacity
high capacity
Amount of resin (cu. ft.)
.78
.78
Rated Softening Capacity (Grains @ Pounds Salt Dose)
11,800 @ 2.3
25,300 @ 7.4
30,200 @ 12.5
11,800 @ 2.3
25,300 @ 7.4
30,200 @ 12.5
Efficiency Rating (Grains / Pound of Salt @ Minimum Salt Dose)
5120 @ 2.3
5120 @ 2.3
Rated Service Flow Rate (gpm)
7.5
7.5
Pressure Drop at Rated Service Flow Rate (psi)
14
14
Intermittent Flow Rate @ 15 psi (gpm)
7.9
7.9
Max. Drain Flow Rate (gpm) to Drain During Regeneration Cycle
2.0