beautypg.com

Installation locations, Product features and specifications – Kidde KN-COPF-I User Manual

Page 6

background image

Recommended Installation Locations

CO alarms should be mounted in or
near bedrooms and living areas. It is
recommended that you install a Kidde
CO alarm on each level of your home.

When choosing your installation loca-
tions, make sure you can hear the
alarm from all sleeping areas. If you
install only one CO alarm in your
home, install it near bedrooms, not in the basement or furnace room.

• When wall mounting, place out of reach of children. Under no cir-

cumstances should children be allowed to handle the CO alarm.

• Placing the alarm at eye level allows for optimum monitoring of the

digital display.

Locations To Avoid

IMPORTANT: Improper location can affect the sensitive electronic com-
ponents in this alarm. To avoid causing damage to the unit, to provide
optimum performance, and to prevent unnecessary nuisance alarms:

• Do not install in kitchens, garages or furnace rooms that may expose

the sensor to substances that could damage or contaminate it.

• Do not install in areas where the temperature is colder than 40°F

(4.4°C) or hotter than 100°F (37.8°C) such as crawl spaces, attics,
porches and garages.

• Do not install within 5 ft. of heating or cooking appliances. (Kidde

recommends 15 ft. to prevent nuisance alarms).

• Do not install near vents, flues, chimneys or any forced/unforced air

ventilation openings.

• Do not install near ceiling fans, doors, windows or areas directly

exposed to the weather.

• Do not install in dead air spaces, such as peaks of vaulted ceilings or

gabled roofs, where CO may not reach the sensor in time to provide
early warning.

• Do not install on a switched or dimmer-controlled outlet.

• Do not install this unit near deep-cell large batteries. Large batteries

have emissions that can cause the alarm to perform at less than opti-
mum performance.

3. Installation Locations

Recommended Locations

Temperature:
Operating Range: 40°F (4.4°C) to 100°F (37.8°C)

Humidity:
Operating range: 10-95% non-condensing

Audible Alarm:
85+ dB at 10’ @ 3.4±0.5 KHz pulsing alarm

Sensor:
Electrochemical

Power:
120 volts AC, 60 Hz, 30 mA max, rechargeable battery back-up

Accuracy of Digital Display (Model KN-COP-IC only):
30-999 PPM +/-30% when measured in conditions of 80° F (+/- 10° F),
atmospheric pressure +/- 10% and 40% +/- 3% relative humidity.
Display readings may vary slightly depending on changes in the ambient
condition (temperature, humidity) and the condition of the sensor.

Alarm Response Times:
70 PPM = 60-240 min., 150 PPM = 10-50 min., 400 PPM = 4-15 min.

Interconnection with Other Alarms:
This Kidde CO alarm can be used as a single-station alarm or intercon-
nected with other Kidde alarms. This alarm can be interconnected direct-
ly with these Kidde models:

Ionization smoke alarm models:
1235, 1235CA, 1275, 1275CA, 1276,1276CA, 1285, 1285CA,
i12020, i12040, i12060, i12080, i12020CA, i12040CA, i12060CA,
RF-SM-ACDC, KN-SMFM-i

Photoelectric smoke alarm models:
PE120, PE120CA, PI2000, PI2000CA

Heat alarm models:
HD135F, HD135FCA

Carbon monoxide/Ionization smoke alarm models:
KN-COSM-IB, KN-COSM-IBCA

Carbon monoxide alarm models:
KN-COB-IC, KN-COP-IC, KN-COB-ICB, KN-COP-ICB

Relay models:
CO120X, SM120X

Strobe Light models:
SL177I

2. Product Features and Specifications