Troubleshooting Procedures (cont.)

Symptoms

Probable Causes

Recommended Action

13.

Noise level from pump

has increased and/or

airjet performance has

decreased.

A.

The check valve is

malfunctioning.

A.

Tap the check valve with a

screwdriver handle. Restart the

system. If the symptoms have

ceased, the check valve does not

need to be replaced.

B.

The check valve needs to be

replaced.

B.

Remove the check valve from the

check valve assembly. Reassemble

the check valve assembly without

the check valve. Restart the system.

If the system properly functions

without the check valve, the check

valve needs to be replaced. For

safety, reinstall the malfunctioning

check valve until a replacement

check valve can be installed.

For Baths with Chromatherapy

Symptoms

Probable Causes

Recommended Action

14.

Chromatherapy lights do

not work.

A.

Loose, disconnected or damaged

wiring/connections.

A.

Check wiring for proper

connections. Replace wiring if

necessary. Refer to your installer or

wholesale dealer.

B.

Control does not work.

B.

Replace control. Refer to your

installer or wholesale dealer.