4

IX AMPLIFIERS

OPERATION

INPUT
LEVEL

REMOTE BASS

LO

HI

INPUT

L

R

OUTPUT

POWER

SPEAKER

GND

+

REM

+12V

AUTO

TURN ON

12V DC AUDIO

OFFSET

Automatic Turn-On Selection: The IX series offers three different automatic turn-on modes that can be
selected on the end panel; +12V, DC Offset, and Audio. Using either the DC Offset or Audio mode causes the
REM terminal to have +12V out for turning on additional amplifi ers.

Remote Turn-On: Set the switch to +12V to use the remote turn-on lead from your source unit. Run 18
gauge wire from the Remote Turn-On Lead on your source unit to the terminal labeled REM between the
amplifi er’s positive and negative power terminals. This is the preferred automatic turn-on method.

DC Offset Turn-On: If Remote Turn-On is not an option, the next best setting is DC Offset. The DC Offset
mode detects a 6V DC offset from the HI-Level speaker outputs when the source unit has been turned on.

• Signal Sense Turn-On: The Audio setting is the fi nal alternative for Automatic turn-on. This is a Signal Sense

turn-on method that detects the incoming audio signal from your source unit and automatically turns on the
amp. This turn-on method will not work properly if the input gain control is not set appropriately.

INPUT
LEVEL

REMOTE BASS

LO

HI

INPUT

L

R

OUTPUT

POWER

SPEAKER

GND

+

REM

+12V

AUTO

TURN ON

12V DC AUDIO

OFFSET

12V

battery

external fuse

external fuse

remote turn-on
(see page 5)

bare-metal
chassis ground

18”

(45cm)

24”

(60cm)

MONO OPERATION

minimum impedance of 2 ohms

woofer