beautypg.com

Kidde Carbon Monoxide Alarm KN-COPP-B-LPM (with Digital Display) User Manual

Page 8

background image

Whenever the alarm is operating, the green Power LED flashes every 30
seconds to indicate the unit is monitoring for CO. If the alarm senses
dangerous levels of CO, the red Alarm LED will flash and the alarm will
emit an audible alarm pattern.

6. Model KN-COPP-B-LPM (with digital display)

Operating Characteristics

5. Model KN-COB-B-LPM Operating Characteristics

Operating and Alarm Characteristics

Function

LED Display

Alarm Sound Unit Status

Recommendation

Normal

Operation

Green LED

flashes every 30

seconds

None

Normal DC

operation (sensing

no CO) and with

good batteries

None

Carbon

monoxide

alarm

Red LED flashes

with beeps.

4 quick beeps,

5 seconds

silence,

repeating

Alarm condition.

Dangerous con-

centrations of CO

detected

Refer to “What to

do When the Alarm

Sounds” (inside front

cover)

Low

battery

Red LED flashes

every 60 seconds

One quick

beep every

60 seconds

Batteries need to be

replaced

Replace all three AA

batteries

Error /

service

alarm

Red LED flashes

every 30 seconds

One quick

beep every

30 seconds

Unit is in error

condition

Error

Red LED

constantly on

Constant

alarm

Very low battery or

unit malfunction

Replace battery.

If condition continues,

unit has malfunc-

tioned. Replace

immediately. Unit will

not respond to CO

Normal

Test/Reset

function

Red LED flashes

with beeps.

4 quick beeps,

5 seconds

silence,

repeated once

Normal operation

when Test/Reset

button is pressed

CO not detected.

Alarm for test pur-

poses only

End of

unit life

indicator

Red LED flashes

two times

every 30 seconds

Two quick

beeps every

30 seconds

End of unit life

Replace unit imme-

diately. Unit will not

respond to to CO

The following table illustrates the possible digital displays, describes the
audible alarm patterns, and the recommended actions to take.

6. Model KN-COPP-B-LPM (with digital display)

Operating Characteristics

When the unit is first powered up, the green Operate LED flashes
once every 30 seconds and the digital display will show three “eights”
– indicating the alarm is in the start-up mode. The three “eights” will
remain for approximately 30 seconds. Then, the alarm will display “0”
and begin monitoring the air for CO and will continue to do so as long
as it receives power.

This alarm will display a “0” if CO concentrations between 0 and 30
PPM have been detected within the last 15 seconds.

Operating and Alarm Characteristics

LCD Display Shows

Alarm Sound

Unit Status

Recommendation

A steady display of

CO concentration

from 30-999. Red

LED flashes with beep

4 quick beeps,

5 secs. silence,

repeating

Alarm condition.

Dangerous

concentrations of

CO detected

Refer to “What to

do When the Alarm

Sounds” (inside front

cover)

Brief “888” for

approximately 30

seconds

None

Self test when first

powered up

None – CO has

not been detected.

Numbers shown for

test purpose only

A random number

is displayed –

between approxi-

mately 150 and 300

4 quick beeps,

5 seconds

silence,

repeated once

Test/Reset button is

pressed

None – CO has

not been detected.

Numbers shown for

test purpose only

Steady “0” displayed,

dot flashing every 5

seconds, Green LED

flashes every 30 secs.

None

Normal DC

operation with

good batteries

(sensing no CO)

None

“Lb” flashes alter-

nately with any

number, Red LED

flashes every 60 seconds.

One quick beep

every 60 seconds

Batteries need to

be replaced

Replace all three AA

batteries immediately

“Err” displayed

One quick beep

every 30 seconds

Unit is Error con-

dition

Replace batteries.

If “Err” (or blank

display) continues,

unit has malfunc-

tioned. Replace

immediately. Unit will

not respond CO

Display is blank

Constant alarm

Unit malfunction

Number from

11-999 displayed.

None

Peak Level Memory

activated. Highest

concentration of

CO detected is

displayed

Refer to following

section for informa-

tion regarding Peak

Level Memory

“End” displayed.

Red LED flashes

two times

every 30 seconds

Two quick

beeps every

30 seconds

End of unit life

Replace unit imme-

diately. Unit will not

respond to CO.

The problems listed above are under normal operating conditions. Other
“Err” conditions could exist. If you should have any questions regarding
display conditions, call our Consumer Hotline.