beautypg.com

Kohler Digital Interface K-684 User Manual

Page 11

background image

Troubleshooting (cont.)

Troubleshooting Table
Symptoms

Probable Cause

Recommended Action

E.

If none of the recommended

actions for the above issues

correct the symptom, the valve

requires servicing.

E.

Contact your Kohler Co. authorized

service representative.

4.

Maximum blend

temperature too hot or

too cold.

A.

Incorrect maximum temperature

setting.

A.

Refer to the

″Set the Maximum

Temperature

″ section in the Digital

Interface Homeowners Guide.

B.

If the above recommended

action does not correct the

symptom, the interface or valve

requires servicing.

B.

Contact your authorized Kohler

service representative.

5.

Continuous flow.

A.

System will not switch off.

A.

Turn off the water and power

supply and contact your Kohler Co.

authorized service representative.

6.

Massage mode shuts

down but water continues

to run from

showerhead(s).

A.

Unequal flow rates between

valve outlets.

A.

Verify the installation has one

bodyspray per valve outlet and

uses bodysprays with the same

flow rate. If needed, contact the

installer to revise the installation.

B.

Fluctuation of inlet pressure.

B.

Install pressure regulators in the

supply lines.

C.

Pressure difference greater than

5 psi (34.5 kPa) between the hot

and cold supply lines.

C.

Install pressure regulators to bring

the supplies with 5 psi (34.5 kPa)

of each other.

7.

Only cold water flows

from the outlets.

A.

Hot water supply is either not

turned on or not connected to

the valve inlet.

A.

Check if the hot water supply is

turned on and connected to the

valve inlet.

B.

Hot water inlet is blocked.

B.

Check if the hot water inlet screen

for blockage. Clean or replace the

inlet screen. Refer to the Valve

Homeowners Guide.

C.

If none of the recommended

actions for the above issues

correct the symptom, the valve

requires servicing.

C.

Contact your Kohler Co. authorized

service representative.

8.

Fluctuating or reduced

flow rate. Valve is

functioning properly.

A.

Inlet/outlet fittings may be

blocked.

A.

Check the inlets and outlets for

blockage or debris. Clean the inlet

screens. Refer to the

″Clean the

Inlet Screens

″ section.

B.

Water outlet pressure is low.

B.

Check that the flow rate is at or

above the minimum rate required.

Refer to

″Specifications″ section in

the Valve Homeowners Guide.

C.

Fluctuating flow.

C.

Verify that the dynamic inlet

pressures are within specifications.

Refer to

″Specifications″ section.

D.

If none of the recommended

actions for the above issues

correct the symptom, the valve

requires servicing.

D.

Contact your Kohler Co. authorized

service representative.

9.

Blend temperature drift or

temperature cycling.

A.

Fluctuating water temperature.

A.

Check the inlet temperature

differentials and verify they are

sufficient. Refer to

″Specifications″

section.

B.

Hot water supply temperature

fluctuation.

B.

Check and make adjustments as

needed.

Kohler Co.

11

1043184-2-B

This manual is related to the following products: