beautypg.com

Placement, Ac power guidelines, Input circuit board – Krell Industries KAV 3250 User Manual

Page 24

background image

Figure 8 Reconfiguring the KAV–2250 for Bridged Operation

1

2

O

N

1

2

O

N

1

S3

S1

Bridge

Channel 1 Input

Channel 2 Input

MT1

J5

J6

S2

Input Circuit Board

Figure 9 Reconfiguring the KAV–3250 for Bridged Operation

Input Circuit Board

3

1

2

O

N

3

1

2

O

N

3

1

2

O

N

1

S4

S1

Bridge

Channel 1 Input

Channel 2 Input

Channel 3 Input

MT1

J7

J8

J9

S3

S2

1

2

O

N

Switch Up (On)

Switch Down (Off)

Bridge Switch Up (On)

Bridge Switch Down (Off)

1

2

3

O

N

KAV–3250 Input Switch Bank

KAV–2250 Input Switch Bank

20

Krell KAV–2250 and KAV–3250

Bridge Channel 1 and 2

Bridge Channel 1 and 2

Krell KAV–2250 and KAV–3250 5

Placement

Before you integrate your new amplifier into your system, please review the following
guidelines to choose the location for the component. This will facilitate a clean, trouble-
free installation.

The amplifier requires at least two inches (5 cm) of clearance on each side and at least
two inches (5 cm) of clearance above and below the component to provide adequate
ventilation.

The amplifier does not require any type of special rack or cabinet for installation. For the
dimensions of your amplifier see

Specifications, on pages 26 and 27.

Place the amplifier as close to the loudspeakers as possible and keep the loudspeaker
cable length to a minimum. Loudspeaker cable adds impedance to the load the amplifier
must drive, regardless of the cable’s gauge. Krell amplifiers drive the lowest
impedances with ease, but long loudspeaker cables reduce the maximum power that is
delivered to the loudspeakers.

AC POWER GUIDELINES

Krell recommends operating the amplifier from a dedicated 15-amp AC power line.
Please contact your authorized Krell dealer, distributor, or Krell before using any
devices designed to alter or stabilize the AC power for the KAV–2250 and KAV–3250.
`
Power Cord
The KAV–2250 and KAV–3250 should be operated only with the power cord supplied.