beautypg.com

Warning, Direct wire method: copper or aluminum wire – KITCHENAID Convection Oven User Manual

Page 7

background image

7

Direct wire method: Copper or Aluminum wire

1. Disconnect power.

2. Remove the knockout as needed for

conduit connection.

3. Assemble a U.L.-

listed conduit
connector in
opening.

This range may be connected directly to
the fuse disconnect or circuit breaker box;
or with a U.L.-listed, 40 amp range power
supply cable. Depending on your
electrical supply, make the required three-
wire or four-wire connection.

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper or 6 gauge
aluminum wire.

Electrically ground range.

Failure to follow these instructions can
result in death, fire, or electrical shock.

WARNING

4. Strip the insulation back 1 inch from

the end of each wire.

5. Allow enough slack in the wire to

easily attach the wiring terminal block.

6. Use 3/8” nut driver and remove the

outside nuts on the terminal block
screws. Do not loosen the factory-
tightened nuts behind the outside nuts.

1”

Use this method only if local codes
permit connecting ground conductor to
neutral supply wire.

10. Loosen (do not remove) the 3 slotted

set screws. Insert the neutral (white)
wire into the hole at the bottom of the
center position lug (attached to center
terminal screw of terminal block). See
Figure 3. Connect the other two wires
(lines 1 and 2) to the outer aluminum
lugs. Securely tighten the set screws.
For 8 gauge copper wire, tighten to
25 in/lbs of torque, and for 6 gauge
aluminum wire, tighten to 35 in/lbs of
torque to make a proper electrical
connection. See Figure 3.

11. Tighten the locking ring of the conduit

connector.

12. Replace the terminal block cover.

Figure 3

Three-wire electrical
connection:

Four-wire electrical
connection:

ground
link

Figure 1

Figure 2

Use this method for new installations,
mobile homes, recreational vehicles and
whenever four-wire installation is
required.

10. Remove the ground-link screw from

the range frame. Save the ground-link
screw and cup washer. Bend up the
ground link so that it does not contact
the range. See Figures 1 and 2.

11. Connect the bare ground wire to the

range using the ground-link screw and
cup washer. The ground wire must be
attached first and must not contact any
other terminal. See Figure 2.

12. Loosen (do not remove) the 3 slotted

set screws. Insert the neutral (white)
wire into the hole at the bottom of the
center position lug (attached to center
terminal screw black terminal block).
See Figure 2. Connect the other two
wires (line 1 and 2) to the outer
aluminum lugs. Securely tighten the
set screws. For 8 gauge copper wire,
tighten to 25 in/lbs of torque, and for

ground
screw

aluminum
lug

terminal
screw

set screw
must face out

slotted
set screw

green
ground
wire

line 1

line 2

neutral
(center
wire)

slotted
set screw

line 1

line 2

neutral
(center
wire)

7. IMPORTANT: the aluminum lugs must

be assembled to the terminal posts
with the set screws facing out as
shown.

6 gauge aluminum wire, tighten to
35 in/lbs of torque to make a proper
electrical connection. See Figure 2.

13. Tighten the locking ring of the

conduit connector.

14. Replace the terminal block cover.

NOTE: The bag containing three
aluminum terminal lugs must be used
when making a direct wire connection.

U.L.-listed
conduit
connector

8. Attach three aluminum lugs to

terminal posts.

Use a 3/8” nut driver and tighten the
nuts securely. Nuts must be tightened
to 20 in/lbs of torque for proper
electrical connection.

9. Complete electrical connection

according to your type electrical
supply (“Four-wire electrical
connection” or “Three-wire electrical
connection.”)