TECHNICAL SPECIFICATIONS

1.3

Model 880 Elite authorized contents

Isotope Assembly

Model Number

Gamma
Energy Range

Half Life

Approximate
Steel Working
Thickness

Device/Source
Maximum
Capacity

Ytterbium-169

91810

8-308 keV

32 days

2-20 mm

20 Ci 0.74 TBq

Selenium-75

A424-25W

66-401 keV

120 days

3-29 mm

150 Ci 5.55 TBq

Iridium-192 A424-9

206-612

keV

74

days

12-63 mm

50 Ci 4.81 TBq

Cobalt-60 A424-19 1.17-1.33

MeV

5.27 years

50-150 mm

25 mCi 925 MBq

Cesium-137

A424-30

663 keV

30 years

12-63 mm

380 mCi 14.0 GBq

Model 880 Omega authorized contents

Isotope Assembly

Model Number

Gamma
Energy Range

Half Life

Approximate
Steel Working
Thickness

Device/Source
Maximum
Capacity

Ytterbium-169

91810

8-308 keV

32 days

2-20 mm

30 Ci 1.11 TBq

Selenium-75

A424-25W

66-401 keV

120 days

3-29 mm

80 Ci 2.96 TBq

Iridium-192 A424-9

206-612

keV

74

days

12-63 mm

15 Ci 0.55 TBq

Source output

Isotope

At 1 m per Ci (37 GBq)

At 1 ft per Ci (37 GBq)

Ytterbium-169

0.125 R/hr

1.25 mSv/hr

1.3 R/hr

13.0 mSv/hr

Selenium-75

0.203 R/hr

2.03 mSv/hr

2.2 R/hr

22.0 mSv/hr

Iridium-192

0.48 R/hr

4.80 mSv/hr

5.2 R/hr

52.0 mSv/hr

Cobalt-60

1.30 R/hr

13.0 mSv/hr

14.0 R/hr

140 mSv/hr

Cesium-137

0.32 R/hr

3.20 mSv/hr

3.4 R/hr

34.0 mSv/hr

Selected attenuation data

Approximate Half Value Thickness

Inches (mm)

Material Approximate

Material
Density
(g/cm

3

)

Ytterbium-169

Selenium-75 Iridium-192 Cobalt-60 Cesium-137

Concrete

2.35

1.140 (29.0)

1.180 (30.0)

1.700 (43.2)

2.400 (61.0)

3.00 (76.2)

Aluminum 2.65

- 1.100

(27.0)

- -

-

Steel

7.80

0.170 (4.3)

0.315 (8.0)

0.512 (13.0)

0.827 (21.0)

0.900 (22.9)

Lead

11.34

0.032 (0.8)

0.039 (1.0)

0.200 (5.1)

0.500 (12.7)

0.250 (6.4)

Tungsten 17.80

- 0.032

(0.8)

0.130 (3.3)

0.310 (7.9)

0.225 (5.7)

DU 18.70 - -

0.050 (1.3)

0.270 (6.8)

0.125 (3.2)

Operating Distance

The distance between the remote control and the exposure head is determined by summing the length of
the remote control conduits plus the total length of source guide tubes used, and normally should not
exceed 47 ft (14.2 m) with standard 25 ft. controls.

Standard remote controls:
25 ft (7.6 m), 35 ft (10.7 m), 50 ft (15 m)

Standard source guide tubes (projection sheaths):
7 ft (2.1 m) set of three source guide tubes: 21 ft total (6.3 m)