Model 880 elite authorized contents, Model 880 omega authorized contents, Source output – SIGMA projetor User Manual
Page 7: Selected attenuation data, Operating distance

TECHNICAL SPECIFICATIONS
1.3
Model 880 Elite authorized contents
Isotope Assembly
Model Number
Gamma
Energy Range
Half Life
Approximate
Steel Working
Thickness
Device/Source
Maximum
Capacity
Ytterbium-169
91810
8-308 keV
32 days
2-20 mm
20 Ci 0.74 TBq
Selenium-75
A424-25W
66-401 keV
120 days
3-29 mm
150 Ci 5.55 TBq
Iridium-192 A424-9
206-612
keV
74
days
12-63 mm
50 Ci 4.81 TBq
Cobalt-60 A424-19 1.17-1.33
MeV
5.27 years
50-150 mm
25 mCi 925 MBq
Cesium-137
A424-30
663 keV
30 years
12-63 mm
380 mCi 14.0 GBq
Model 880 Omega authorized contents
Isotope Assembly
Model Number
Gamma
Energy Range
Half Life
Approximate
Steel Working
Thickness
Device/Source
Maximum
Capacity
Ytterbium-169
91810
8-308 keV
32 days
2-20 mm
30 Ci 1.11 TBq
Selenium-75
A424-25W
66-401 keV
120 days
3-29 mm
80 Ci 2.96 TBq
Iridium-192 A424-9
206-612
keV
74
days
12-63 mm
15 Ci 0.55 TBq
Source output
Isotope
At 1 m per Ci (37 GBq)
At 1 ft per Ci (37 GBq)
Ytterbium-169
0.125 R/hr
1.25 mSv/hr
1.3 R/hr
13.0 mSv/hr
Selenium-75
0.203 R/hr
2.03 mSv/hr
2.2 R/hr
22.0 mSv/hr
Iridium-192
0.48 R/hr
4.80 mSv/hr
5.2 R/hr
52.0 mSv/hr
Cobalt-60
1.30 R/hr
13.0 mSv/hr
14.0 R/hr
140 mSv/hr
Cesium-137
0.32 R/hr
3.20 mSv/hr
3.4 R/hr
34.0 mSv/hr
Selected attenuation data
Approximate Half Value Thickness
Inches (mm)
Material Approximate
Material
Density
(g/cm
3
)
Ytterbium-169
Selenium-75 Iridium-192 Cobalt-60 Cesium-137
Concrete
2.35
1.140 (29.0)
1.180 (30.0)
1.700 (43.2)
2.400 (61.0)
3.00 (76.2)
Aluminum 2.65
- 1.100
(27.0)
- -
-
Steel
7.80
0.170 (4.3)
0.315 (8.0)
0.512 (13.0)
0.827 (21.0)
0.900 (22.9)
Lead
11.34
0.032 (0.8)
0.039 (1.0)
0.200 (5.1)
0.500 (12.7)
0.250 (6.4)
Tungsten 17.80
- 0.032
(0.8)
0.130 (3.3)
0.310 (7.9)
0.225 (5.7)
DU 18.70 - -
0.050 (1.3)
0.270 (6.8)
0.125 (3.2)
Operating Distance
The distance between the remote control and the exposure head is determined by summing the length of
the remote control conduits plus the total length of source guide tubes used, and normally should not
exceed 47 ft (14.2 m) with standard 25 ft. controls.
Standard remote controls:
25 ft (7.6 m), 35 ft (10.7 m), 50 ft (15 m)
Standard source guide tubes (projection sheaths):
7 ft (2.1 m) set of three source guide tubes: 21 ft total (6.3 m)