beautypg.com

Trouble shooting guide, Operating instructions spécifications techniques – Shark EP602RF User Manual

Page 11

background image

TROUBLE SHOOTING GUIDE

IMPORTANT

: This unit is equipped

with a motor protective thermostat. If

for some reason the vacuum cleaner

should overheat, the thermostat will

automatically turn the unit off. Should

this occur:

Push the On/Off button once.

Disconnect the plug from the

power source.

Check the source of overheating

problem. (i.e. clogged hose or

filter)

Motor Thermostat

• If clogged hose or filter is found,

unclog the hose and replace the

filters.

• Wait at least 45 minutes before

attempting to reuse the vacuum.

• After unit has cooled down for

45 minutes, plug in the cleaner

and push the On/Off button. The

vacuum should start again.

• If the vacuum still does not start,

contact customer service at

1-800-798-7398.

PROBLEM

POSSIBLE REASON

POSSIBLE SOLUTION

VACUUM WILL

NOT OPERATE

1.

Power cord not firmly plugged into
outlet.

2.

No power in wall outlet.

3. Needs

servicing.

4.

Thermostat has tripped.

1.

Plug unit in firmly.

2.

Check fuse or breaker. Replace
fuse/reset breaker.

3. Call

1-800-798-7398.

4.

Turn the unit off and unplug from
outlet. Allow unit to cool down,
then restart.

VACUUM WILL

NOT PICK-UP OR

SUCTION POWER

IS WEAK

1.

Dust cup is full.

2. Unit

clogged.

3.

HEPA Filter needs cleaning or
replacing.

4.

Debris screen needs cleaning.

5. Filters

need

cleaning

1.

Empty and clean dust cup.

2.

Turn unit off and unplug from
wall outlet. Remove Dust Cup
Filter and check for object(s) in
air duct and remove.

3.

Clean or replace HEPA Filter.

4.

Clean debris screen.

5. Clean

Filters

TURBO BRUSH

DOES NOT

ROTATE OR

ROTATES

SLOWLY

1.

Dust cup is full.

2.

Rotating brush or elbow is
obstructed.

3. Belt

is

broken.

4. Hose

obstructed.

5.

Debris screen is clogged.

6. Filters

need

cleaning.

1.

Empty dust cup.

2. Clear

obstructions.

3. Call

1-800-798-7398.

4. Clear

obstruction.

5.

Clean debris screen.

6.

Clean All filters.

DUST ESCAPING

FROM VACUUM

1.

Dust cup is full.

2.

Dust Cup is not installed correctly.

1.

Empty and clean dust cup.

2.

Review Dust Cup instructions.

VACUUM, HOSE

OR BRUSHES

WILL NOT PICK-UP

1. Hose

clogged.

2.

Dust cup is full.

1.

Remove hose and/or brushes.
Remove obstruction from hose
and /or brush.

2.

Empty and clean dust cup.

FAMILIARISEZ-VOUS AVEZ VOTRE ASPIRATEUR

TRANSFORMER VAC

1.

Poignée

2.

Tube télescopique

3.

Bouton de verrouillage

4.

Boyau souple

5.

Bouton 1 de relâche de la
coupelle

6.

Poignée de la coupelle

7.

Coupelle à poussière

8.

Boîtier principal

9.

Surveille-filtre Intelli-

Sense

MC

10. Couvercle du filtre

d’échappement

11. Commutateur marche/arrêt
12. Cordon d’alimentation
13. Bouton de relâche de la

brosse à planchers

14. Brosse à planchers
15. Suceur plat
16. Brosse à épousseter
17. Bouton de relâche du tube

télescopique

18. Bouton 2 de relâche de la

coupelle

19. Relâche du crochet à

cordon

20. Raccord du boyau
21. Bandoulière (non illustrée)
22. Brosse turbo actionnée à

l’air

22

OPERATING INSTRUCTIONS

Spécifications techniques

Tension :

120 V., 60 Hz.

Puissance :

10 amps

*Les illustrations peuvent différer du produit lui-même.

9