Trouble shooting guide, Operating instructions spécifications techniques – Shark EP602RF User Manual
Page 11
TROUBLE SHOOTING GUIDE
IMPORTANT
: This unit is equipped
with a motor protective thermostat. If
for some reason the vacuum cleaner
should overheat, the thermostat will
automatically turn the unit off. Should
this occur:
•
Push the On/Off button once.
•
Disconnect the plug from the
power source.
•
Check the source of overheating
problem. (i.e. clogged hose or
filter)
Motor Thermostat
• If clogged hose or filter is found,
unclog the hose and replace the
filters.
• Wait at least 45 minutes before
attempting to reuse the vacuum.
• After unit has cooled down for
45 minutes, plug in the cleaner
and push the On/Off button. The
vacuum should start again.
• If the vacuum still does not start,
contact customer service at
1-800-798-7398.
PROBLEM
POSSIBLE REASON
POSSIBLE SOLUTION
VACUUM WILL
NOT OPERATE
1.
Power cord not firmly plugged into
outlet.
2.
No power in wall outlet.
3. Needs
servicing.
4.
Thermostat has tripped.
1.
Plug unit in firmly.
2.
Check fuse or breaker. Replace
fuse/reset breaker.
3. Call
1-800-798-7398.
4.
Turn the unit off and unplug from
outlet. Allow unit to cool down,
then restart.
VACUUM WILL
NOT PICK-UP OR
SUCTION POWER
IS WEAK
1.
Dust cup is full.
2. Unit
clogged.
3.
HEPA Filter needs cleaning or
replacing.
4.
Debris screen needs cleaning.
5. Filters
need
cleaning
1.
Empty and clean dust cup.
2.
Turn unit off and unplug from
wall outlet. Remove Dust Cup
Filter and check for object(s) in
air duct and remove.
3.
Clean or replace HEPA Filter.
4.
Clean debris screen.
5. Clean
Filters
TURBO BRUSH
DOES NOT
ROTATE OR
ROTATES
SLOWLY
1.
Dust cup is full.
2.
Rotating brush or elbow is
obstructed.
3. Belt
is
broken.
4. Hose
obstructed.
5.
Debris screen is clogged.
6. Filters
need
cleaning.
1.
Empty dust cup.
2. Clear
obstructions.
3. Call
1-800-798-7398.
4. Clear
obstruction.
5.
Clean debris screen.
6.
Clean All filters.
DUST ESCAPING
FROM VACUUM
1.
Dust cup is full.
2.
Dust Cup is not installed correctly.
1.
Empty and clean dust cup.
2.
Review Dust Cup instructions.
VACUUM, HOSE
OR BRUSHES
WILL NOT PICK-UP
1. Hose
clogged.
2.
Dust cup is full.
1.
Remove hose and/or brushes.
Remove obstruction from hose
and /or brush.
2.
Empty and clean dust cup.
FAMILIARISEZ-VOUS AVEZ VOTRE ASPIRATEUR
TRANSFORMER VAC
1.
Poignée
2.
Tube télescopique
3.
Bouton de verrouillage
4.
Boyau souple
5.
Bouton 1 de relâche de la
coupelle
6.
Poignée de la coupelle
7.
Coupelle à poussière
8.
Boîtier principal
9.
Surveille-filtre Intelli-
Sense
MC
10. Couvercle du filtre
d’échappement
11. Commutateur marche/arrêt
12. Cordon d’alimentation
13. Bouton de relâche de la
brosse à planchers
14. Brosse à planchers
15. Suceur plat
16. Brosse à épousseter
17. Bouton de relâche du tube
télescopique
18. Bouton 2 de relâche de la
coupelle
19. Relâche du crochet à
cordon
20. Raccord du boyau
21. Bandoulière (non illustrée)
22. Brosse turbo actionnée à
l’air
22
OPERATING INSTRUCTIONS
Spécifications techniques
Tension :
120 V., 60 Hz.
Puissance :
10 amps
*Les illustrations peuvent différer du produit lui-même.
9
24