Accessories
If an extension cord is
necessary, a cord with
adequate size conductors that is capable
of carrying the current necessary for your
tool must be used. This will prevent
excessive voltage drop, loss of power or
overheating. Grounded tools must use 3-
wire extension cords that have 3-prong plugs
and receptacles.
NOTE: The smaller the gauge number, the
heav i er the cord.
RECOMMENDED SIZES OF ExTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
!
WARNING
Tool’s
Ampere
Rating
Cord Size in A.W.G.
Wire Sizes in mm
2
3-6
6-8
8-10
10-12
12-16
18
16
16
14
0.75 0.75 1.5
2.5
18
16
14
12
0.75 1.0
2.5
4.0
18
16
14
12
0.75 1.0
2.5
4.0
16
16
14
12
1.0
2.5
4.0
—
14
12
—
—
—
—
—
—
25
50
100
150
15
30
60
120
Cord Length in Feet
Cord Length in Meters
* Double-Ended Screwdriver Bit
** Carrying Case
(* = standard equipment)
(** = optional accessories)
Extension Cords
Trouble Shooting
Read instruction manual first! Remove battery pack from the tool before making
adjustments or assembling accessories.
TROUBLE: TOOL WILL NOT START
PROBLEM
1. Battery pack not charged.
2. Battery pack not installed properly.
3. Battery pack temperature is too hot or cold for operation.
4. Burned out switch.
REMEDY
1. If equipped, check battery charge condition lights for charge status.
Charge battery if needed.
2. Confirm battery is locked and secured to the tool.
3. Let battery sit a few minutes or until it reaches normal operating
temperature.
4. Have switch replaced by an Authorized Skil Service Center or Service Station.
TROUBLE: BATTERY PACK WILL NOT CHARGE
PROBLEM
1. Charger not plugged into outlet.
2. Battery pack not completely inserted into charger.
REMEDY
1. Confirm charger is plugged into outlet.
2. Confirm battery pack is inserted into charger completely.
!