TROUBLESHOOTING

Performance problems often can be corrected by the user. Please completely read
this chart for possible solutions to common problems.

PROBLEM

POSSIBLE CAUSE

SOLUTION

Check RED light Is on.

The battery is not connected

Connect or adjust clips.

correctly.

Check for correct polarity.

The battery is less than one

Replace the battery or try

volt.

using a manual charger to
bring above 1 volt.

Indicator lights are lit in an

A button may have been

Make sure nothing is

erratic manner not explained

pressed when the charger

touching the control panel,

in the “Using Your Battery

was plugged in.

then unplug the unit and

Charger” section.

plug it in again.

The charger may be

Return to place of purchase

defective.

for replacement.

The Check RED light is

Charger in abort mode.

See “Using Your Battery

flashing.

Battery may be bad.

Charger."

The CHECK (red) light

This will happen if the

Reset the charger by un-

always flashes before the

battery did not reach full

plugging it or briefly discon-

battery is completely

charge within 24 hours. May

necting the negative battery

charged.

be due to a very large

clip. Select the desired

battery or a bank of batteries

charge rate and battery type

requiring more power than

again, if necessary.

the charger can deliver in
24 hours. Battery may also
be faulty.

The green CHARGED light

The battery may be fully

If the battery is in a vehicle,

turns on a few minutes after

charged or recently charged,

turn the headlights on for a

connecting to the battery.

leaving the battery voltage

few minutes to reduce the

high enough to appear to be

battery voltage and try

fully charged.

charging again. Also try a
lower CHARGE RATE
selection.

The charger is making an

The charger has a relay that

No problem, this is a normal

audible clicking sound.

turns the current on and off

condition.

to the battery.