beautypg.com

Adjusting engine idle stopping the engine, Starting a flooded engine – Shindaiwa HT2510/EVC User Manual

Page 7

background image

7

The engine

must return to idle speed

whenever the throttle lever is released.

Idle speed is adjustable, and

must be set

low enough to permit the engine clutch to

disengage the cutters.

Adjusting Engine Idle

Stopping the Engine

Idle Adjustment Screw

1. Cool the engine by allowing it to idle for

–3 minutes.

. Move the ignition switch to the “O” or

STOP position. See Figure 11.

WARNING!

The cutters must NEVER engage at
engine idle speeds! If the idle speed
cannot be adjusted by the above
procedure, return the trimmer to your
dealer for inspection.

Idle Speed Adjustment

1. Start the engine, and then allow it to idle

–3 minutes until warm.

. If the cutters move when the engine is

at idle, reduce idle speed by turning the

idle adjustment screw counterclockwise.

3. If a tachometer is available, the engine

idle speed should be final-adjusted to

3,000 ±50 rpm (min

-1

).

4. Carburetor fuel mixture adjustments

are preset at the factory and cannot be

adjusted or serviced in the field.

Figure 10

Starting a Flooded Engine

Spark

Plug

Spark Plug

Lead

CAUTION!
Incorrect spark plug installation can
damage the engine!

1. Disconnect the spark plug lead, and

then use the spark plug wrench to

loosen and remove the spark plug.

. If the spark plug is fouled or is soaked

with fuel, clean or replace the plug as

necessary. For spark plug specifications

and gapping procedure, see page 9.

3. With the spark plug removed, crank the

engine several times to clear excess fuel

from the combustion chamber.

WARNING!

Burn danger from hot engine! Allow
engine to cool before removing
cylinder cover.

Figure 9

4. Replace the spark plug and tighten it

firmly with the spark plug wrench. If a

torque wrench is available, torque the

spark plug to 170-190 kg cm.

5. Repeat the starting procedures for a

warm engine.

6. If the engine still fails to start or fire,

refer to the troubleshooting chart at the

end of this manual.

DH2510

Figure 11

HT2510

Ignition OFF

Ignition

Switch

Ignition

Switch

Ignition OFF