beautypg.com

Gearcase lubrication, Hour or annual maintenance, Blades – Shindaiwa HT2510/EVC User Manual

Page 10

background image

10

Gearcase Lubrication

VIEWED FROM THE BOTTOM

Gearcase Grease Fitting

CAUTION!
n

Over-lubricating may cause the

gearcase to run slower than normal,

and may also cause leakage from

excess grease.

Every 20 Hours

Figure 21

VIEWED FROM

THE BOTTOM

Gearcase

Cover

Figure 20

Top off gearcase grease level by using a le-

ver-type grease gun to force 1– strokes of

high quality lithium-based grease through

the gearcase grease fitting.

Every 100 Hours

(or before long-term storage)

139-Hour or Annual Maintenance

NOTE:

The NGK CMR5H also meets the require-

ments for electro magnetic compliance (EMC).

Valve Adjustment

1. Remove cylinder cover, rocker arm cover,

and set piston at TDC-compression.

. Loosen adjuster locknut so that the

.5 mm Allen socket head adjustment

screw can turn freely.

3. Insert feeler gauge .004 (0.10 mm) for

both intake and exhaust; between valve

stem tip and rocker arm.

7. Replace rocker arm cover gasket to as-

sure proper sealing and install cover.

IMPORTANT!

If new gasket is not available and/or old

gasket is not damaged, old gasket may be

reused. Never use cracked or damaged

gaskets!

CAUTION!
n

Performing a valve adjustment

incorrectly may cause hard starting

and/or can damage the unit. Refer to

the C4 Service Manual for complete

valve adjustment procedure and

torque specifications.

n

If you are unfamiliar with this engine

or uncomfortable with this proce-

dure, Consult with an authorized

Shindaiwa servicing dealer.

4. Turn adjustment screw (clockwise =

tighter, counter-clockwise = looser) until

feeler gauge is almost snug. Back off

just enough to allow gauge to slip out

with limited resistance.

5. While holding adjustment screw in place with

Allen driver, tighten locknut with wrench.

6. Turn engine over several times, and return

to TDC-compression. Recheck with proper

feeler gauge to make sure clearance adjust-

ment did not change as a result of tighten-

ing locknut. Readjust as necessary.

Figure 23

Figure 24

Figure 25

Maintenance after first 139-hours,

then every 150-hours thereafter.

n

Combustion chamber should be decar-

bonized, and the valve clearance should

be adjusted. It is highly recommended

that this is done by a Shindaiwa-trained

service technician.

n

Replace the spark plug annually: Use

only NGK CMR5H or equivalent resis-

tor type spark plug of the correct heat

range. Set spark plug electrode gap to

0.6 -0.7 mm.

HT2510_20

Blades

Standard blades require no periodic adjust-

ments. Make sure all blade shoulder bolts

are tight and in good condition.
n

Clean blades and apply a light coating of

oil to all metal surfaces. Vegetable oils

may be used to protect sensitive plants

from spotting.

Locknut

Cutters

Socket Head

Shoulder Bolt

Plate

Guide Bar

Figure 22

Spacer

Remove the gearcase cover, and use

solvent and a soft brush to remove all

old grease from the gearcase. To refill,

hand-pack the gearcase with approximately

40–50 grams of high quality lithium-based

grease (50–70% of capacity). DO NOT

OVERFILL!

Figure 23

Figure 25

This manual is related to the following products: