XLogic Multichannel Compressor Owner’s Manual
Distortion Null
Equipment Required:
Calibrated audio oscillator, audio distortion analyser and oscilloscope
Test Signal:
1kHz sinewave at +24dBu
Input and Output:
Oscillator to the Input of the channel being tested, Output to the distortion
analyser. Use the oscilloscope to monitor the measured signal.
Adjustment:
1. Connect the +ve input of the analyser to the test point as shown below and
connect the –ve input of the analyser to a 0VA test point. Note that the circuitry
at this point is balanced and so there are two measurements and two adjustments
per channel. Adjust for minimum THD (< 0.007%).
Input
Measure
Adjust
Left (+ve)
TP31
VR24
Left (–ve)
TP32
VR23
Right (+ve)
TP29
VR22
Right (–ve)
TP30
VR21
Centre (+ve)
TP27
VR20
Centre (–ve)
TP28
VR19
LFE (+ve)
TP21
VR14
LFE (–ve)
TP22
VR13
Left Sur (+ve)
TP23
VR16
Left Surr (–ve)
TP24
VR15
Right Surr (+ve)
TP25
VR18
Right Surr (–ve)
TP26
VR17
2. Finally, re-connect the analyser to each output in turn and adjust the +ve
distortion null to see if any reduction in THD can be achieved.
VCA Gain Adjust
Equipment Required:
Calibrated audio oscillator, audio level meter, oscilloscope and a (digital) DC
voltmeter
Test Signal:
1kHz sinewave at +20dBu
Input and Output:
Oscillator to the Input of the channel being tested, Output to the level meter. Use
the oscilloscope to monitor the measured signal.
Unit Setup:
1. Switch the Master Fader IN.
2. Using the DVM, measure TP5 on the upper card (629607) and adjust the front
panel Master Fader for –2.00V ±1mV (which equates to 40dB attenuation).
Adjustment:
1. Connect the audio level meter to each output in turn. Measure each channel,
adjusting the appropriate preset for –20dBu ±0.1dB (which equates to 40dB of
attenuation).
Input
Adjust
Left
VR30
Right
VR29
Centre
VR34
LFE
VR36
Left Surround
VR27
Right Surround
VR28