Sharp AF-S120EX User Manual
Page 6
6
INSTALLATION INSTRUCTIONS
Open the window sash and place the
cabinet on the sill.
Close the window sash securely behind
the top angle.
If there is space between the bottom
channel and the sill, fill the gap with a thin
board or other hard filler.
7
Closure assembly
Insert the right closure assembly and the
left closure assembly into the top angle
and the bottom channels.
Secure the right and left closure to the
cabinet with 6 of the provided screws.
(L=
1
/
4
", 6mm)
6
WARNING
Cabinet
sill
incline backwards about 1cm (3/8")
At this step, make sure the cabinet is inclined
approximately 1 cm (3/8”) to the back.
If the cabinet is not properly inclined, the
water collected in the bottom tray during
operation will not drain properly and may
flow into the room where the air condi-
tioner is installed.
Unscrew the 5 stopper screws of the
cabinet. Keep the 3 screws from the
front and side, as they will be used later.
Slide the chassis out from the cabinet
by pulling on the hand hold located at
the bottom both sides of the chassis.
(1)
3
(2)
Do not remove any other material (ex.
styrofoam, etc.) from inside the unit.
CAUTION:
Attach the top angle to the cabinet with 3
gold screws (
1
/
4
", 6mm) .
5
Top angle
Remove the tape and the compressor pad
from the unit.
4
Compressor pad
Tape