PROBLEM

POSSIBLE CAUSE

REASON/SOLUTION

Ammeter reads less than

selected charge rate when

charging a discharged

battery

Extension cord is too long

or wire gauge is too small.

Weak cell or sulfated plate

in battery.

Battery is only partially

discharged.

Use a shorter or heavier

gauge extension cord.

A sulfated battery will

eventually take a normal

charge if left connected. If

the battery will not take a

charge, have it checked.

Continue to charge the

battery.

The charger is making an

audible clicking sound.

Circuit breaker is cycling.

Battery is defective.

Shorted battery cables or

clips.

Severely discharged

battery, but otherwise it is a

good battery.

Reverse connections at

battery.

The settings may be wrong.

Check the charger settings.

Have the battery checked.

Circuit breaker cycles when

current draw is too high.

Check for shorted cables

or clips and replace if

necessary.

The battery may not want

to accept a charge due to

a run-down state. Allow

charging to continue until

battery has a chance to

recover sufficiently to take

a charge. If more than 20

minutes, stop charging and

have the battery checked.

Shut the charger off

and correct the lead

connections.

Charger makes a loud

buzz or hum.

Transformer laminations

vibrate (buzz).

Shorted Diode Assembly or

Output Rectifier Assembly

(hum).

No problem, this is a normal

condition.

Have charger checked by a

qualified technician.