Flow Chart of Troubleshooting
This Document can not be used without Samsung's authorization
9-3
9-2. Initial
PON_RESET_N ="H"?
Initial Failure
Check the circuit related to reset
END
No
Yes
Is TP300~309
OK?
OK
Not OK
Yes
Check the circuit related to memory
Check the circuit around
LCD (short or unsolder)