Server Technology CDUCW-24V4 User Manual
Sentry switched cdu, Cw-24v4, Key features
Sentry : Solutions for the Data Center Equipment Cabinet
Sentry : CDU Technical Specifications
Sentry Switched CDU
Input Current Monitoring
Exclusive True RMS current monitoring is critical to
preventing overloads in high-density computing
environments. LED digital displays on the CDU enclosure
report the input current of each phase or branch circuit.
Temperature and Humidity
The Switched CDU supports two external 10’ (3m) probes.
Each of these probes measure both temperature and
humidity. Receive SNMP-based alerts or email notifications
when conditions exceed defined thresholds.
CW-24V4
High Density Power Distribution
The Switched CDU’s combine remote configuration and management
with power distribution and power and environmental monitoring.
Reboot a single or dual-power server with one command. Receive
SNMP or email based alerts when power or environmental conditions
exceed thresholds. Assign users specific access rights to designated
outlets or groups.
Only the Switched CDU products provide the flexibility needed for all
data centers and remote sites, including power requirements for
high-amp, high voltage; UL 60950-1 branch circuit protection; SSL &
SSH security; and SNMP-based input current monitoring.
> High Density: Single-power
input feed; 24 outlets per
enclosure
> High Power Distribution:
Three-Phase 400V power; 16 or
32-Amp power input feed
options with 230V output
> Input Current Monitor:
Precisely measure the aggregate
current draw (in amps) on each
power circuit. On-site
verification of the input current
with the LED digital display.
Remote verification via web
browser or serial screen.
> IP Access & Security: Web
interface, SSL, SSH, Telnet, SNMP,
FTP, SNTP, Syslog, LDAP, LDAPS,
TACACS
and RS-232 access
> SNMP Traps: Provide automated
alerts for power and
environmental conditions
> Power-up Sequencing: Prevent
an in-rush power overload
> Environmental Monitoring:
Each Switched CDU supports two
external temperature & humidity
probes and reports conditions
thru the user interface without
the need for additional IP
addresses
> Add an Expansion Module:
Daisy chain the Switched CDU
Expansion Module (CW/CX) for
power monitoring of separate
power circuits from a single IP
address
Key Features
Model
Available Input
Voltages
Outlets
Available Input
Cord
Amperage
Dimensions**
(L x W x D)
69.0 x 1.75 x 2.25 in.
(1753 x 44.4 x 57 mm)
69.0 x 1.75 x 2.25 in.
(1753 x 44.4 x 57 mm)
69.0 x 1.75 x 2.25 in.
(1753 x 44.4 x 57 mm)
Additional Features and Specifications
Branch Circuit Protection
> Compliant to UL 60950-1
Agency Approvals
> US & Canada (cTUVus mark) to UL 60950-1:2003
and CAN/CSA 22.2 No. 60950-1-03
> European Union (TUVGS mark) to EN 60950-1:2001
> FCC Class A, Part 15
> CE
> EMC - EN 55022 Class A, EN 55024
Communications and Security
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPS/LDAPv3
> TACACS+
> RS-232 (Serial)
Accessories
> Optional Temperature & Humidity Probe
EMTH-1-1 Temperature & Humidity Probe, 10 ft (3m)
© Server Technology, Inc. 12/2007 version. Information in this document is subject to change without notice. Sentry and Server Technology are trademarks of Server Technology, Inc. Patent # 7,043,543. Patents Pending. Printed in US.
Additional Benefits:
CW-24V4J411
CW-24V4K411
3-Phase, 400 V
50/60Hz
3-Phase, 400 V
50/60Hz
IEC 60309
Cordset, 10 ft (3m)
IEC 60309
Cordset, 10 ft (3m)
(24) IEC 60320/C13
(24) IEC 60320/C13
CX-24V4J411*
3-Phase, 400 V
50/60Hz
3-Phase, 400 V
50/60Hz
IEC 60309
Cordset, 10 ft (3m)
IEC 60309
Cordset, 10 ft (3m)
CX-24V4K411*
(24) IEC 60320/C13
(24) IEC 60320/C13
16A
16A
32A
32A
* CX part numbers refer to the Expansion CDU
**Please note that the depths of these enclosures are 3.30 in. (84mm) deep at the placement of the circuit breakers
APAC
Server Technology Intl
37th Floor, Singapore Land Tower
50 Raffles Place
Singapore 048623
+65 (0) 6829 7008 Tel
+65 (0) 6234 4574 Fax
[email protected]
HEADQUARTERS - NORTH AMERICA
Server Technology, Inc.
1040 Sandhill Drive
Reno, NV 89521
United States
1.775.284.2000 Tel
1.775.284.2065 Fax
[email protected]
www.servertech.com
www.servertechblog.com
EMEA
Server Technology Intl
Sienna Court
The Broadway
Maidenhead
Berkshire
SL6 1NJ
United Kingdom
+44 (0) 1628 509053 Tel
+44 (0) 1628 509100 Fax
[email protected]
Branch Circuit Protection
The Sentry CDU Family meets the UL 60950-1 requirement
for Branch Circuit Protections
> UL-489 rated circuit breakers
69.0 x 1.75 x 2.25 in.
(1753 x 44.4 x 57 mm)
Expansion Modules
> CX-24V4J411
> CX-24V4K411