Sanyo HR-4UC User Manual
Specifications, Typical characteristics, Cell type hr-4uc
Size : AAA
650mAh
600mAh
1.2V
Fast Charge
2)
650 mA x about 1.1h
Charge
Condition
Fast Charge
2)
0°C - 40°C
0°C - 50°C
Less than
30days
-20°C - 50°C
Less than
90days
-20°C - 40°C
Less than
1year
-20°C - 30°C
About 13 g
10.5(D) x 44.5(H) mm
Typical Characteristics
Charge
Discharge
1)Single cell capacity under the following condition.
Dimensions
(with tube)
Specifications
Cell Type HR-4UC
Charge : 65mA×16h, Discharge : 130mA(E.V.=1.0V) at 20°C
Nominal Voltage
Discharge Condition
Weight
4)
Size
4)
:(Diameter) x (Height)
Type : Nickel-Metal Hydride Battery
Internal Impedance
3)
(after discharge to E.V.=1.0V)
Charging Current x Time
D
H
10.5 mm
44.5 mm
2)Use recommended charging system.
3)After a few charge and discharge cycles under the above 1) condition.
4)With tube.
44.5 mm
Ambient Temp.
Storage
Condition
10.5 mm
Capacity
1)
Typical
Minimum
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
0
100
200
300
400
500
600
700
Discharge Capacity (mAh)
Cell Voltage (V)
Charge : 65mA x 16h
Rest : 1h
Discharge : 130mA, 650mA, 1300mA (E.V.=1.0V)
Ambient Temp. : 20°C
130mA
650mA
1300mA
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
0
10
20
30
40
50
60
70
80
Charge Time (min)
Cell Voltage (V)
Charge : 650mA (-
∆
V=10mV)
Ambient Temp. : 0°C,20°C,40°C
0°C
20°C
40°C
About 40mΩ(at 1000Hz)