4.4.5
F100 SM – Subnet Mask
To return the subnet mask of the NET Port, send the following command:
F100 SM
The unit responds:
F100 SM:nnn.nnn.nnn.nnn
An example of the response is:
F100 SM:255.255.255.125
Changing the Subnet Mask requires the unit to reset. A verification prompt appears
prior to execution.
To set the subnet mask and restart the unit, send the following command:
F100 SM:nnn.nnn.nnn.nnn
Sample entry:
F100 SM:255.255.255.240
The response is:
Are you sure?(y/N)
As a safety feature, after sending this command, you have 10 seconds to respond
affirmatively (enter the letter “y”) to the confirmation prompt, after which the unit
executes the command and resets. Within that 10 second time period, any other response,
including no response, results in the unit canceling the command.
4.4.6
F100 G – Gateway
To obtain the Default Gateway of the unit NET Port, send the following command:
F100 G
The unit responds:
F100 G:nnn.nnn.nnn.nnn
An example of the response is:
F100 G:206.54.0.1
Changing the Default Gateway requires the unit to reset. A verification prompt
appears prior to execution.
To set the Default Gateway and restart the unit, send the following command:
F100 G:nnn.nnn.nnn.nnn
Sample entry:
F100 G:206.54.0.17
The response is:
Are you sure?(y/N)
As a safety feature, after sending this command, you have 10 seconds to respond
affirmatively (enter the letter “y”) to the confirmation prompt, after which the unit
executes the command and resets. Within that 10 second time period, any other response,