Sharp AR-156 User Manual
Page 32
30
5
Copier trouble?
Rotate the feeding roller in the direction of the arrow and gently remove the misfed
paper from the exit area.
Feeding roller
Raise the fusing unit release lever, close the front cover and then close the side cover
by pressing the round projections near the side cover open button. The misfeed (
)
indicator will go out and the ready (
) indicator will light up.
When closing the covers, be sure to close the front cover securely and then
close the side cover. If the covers are closed in the wrong order, the covers
may be damaged.
D Misfeed in the RSPF
An original misfeed may occur at one of three locations: if the misfed original is seen from the
document feeder tray, (A) in the document feeder tray; if the misfed original is not seen from
the document feeder tray, (B) in the exit area or (C) under the feeding roller. Remove the misfed
original following the instructions for each location.
(A)
Open the feeding roller cover and pull the original gently to the left and out from the
document feeder tray. Close the feeding roller cover. Open and close the original cover to
clear the RSPF misfeed ( ) indicator.
If the misfed original cannot be easily removed, proceed to (C).
Feeding roller cover
(B)
Open the original cover and rotate the roller rotating knob to remove the misfed original
from the exit area.
If the misfed original cannot be easily removed, proceed to (C).
MISFEED REMOVAL