Figure 31. fos compare, Table 41. fos reference clock selection, Table 42. clknrate registers – Silicon Laboratories SI5375 User Manual
Page 86: S i 5 3 x x - r m

S i 5 3 x x - R M
86
Rev. 1.2
FOS reference. When the XA/XB input is used as the FOS reference, there is only one reference frequency band
that is allowed: from 37 MHz to 41 MHz.
Both the FOS reference and the FOS monitored clock must be divided down to the same clock rate and this clock
rate must be between 10 MHz and 27 MHz. As can be seen in Figure 31, the values for P and Q must be selected
so that the FOS comparison occurs at the same frequency. The registers that contain the values for P and Q are
the CKINnRATE[2:0] registers.
Figure 31. FOS Compare
The frequency band of each input clock must be specified to use the FOS feature. The CLKNRATE registers
specify the frequency of the device input clocks as shown in Table 42.
When the FOS reference is the XA/XB oscillator (either internal or external), the value of Q in Figure 31 is always
2, for an effective CLKINnRATE of 1, as shown in Table 42.
Table 41. FOS Reference Clock Selection
FOS Reference
FOSREFSEL[2:0]
Si5326
Si5368
000
XA/XB
XA/XB
001
CKIN1
CKIN1
010
CKIN2 (default)
CKIN2 (default)
011
Reserved
CKIN3
100
Reserved
CKIN4
all others
Reserved
Reserved
Table 42. CLKnRATE Registers
CLKnRATE
Divisor, P or Q
Min Frequency, MHz
Max Frequency, MHz
0
1
10
27
1
2
25
54
2
4
50
105
3
8
95
215
4
16
190
435
5
32
375
710
CKIN
FOS_REF
P
Q
FOS
Compare
10 MHz min,