beautypg.com

Schumacher 00-99-000659 User Manual

Page 8

background image

8

110V aC eleCtriCal DeViCe example run-time Chart

Appliance type

estimated Wattage

estimated time*

Spotlights, Sump Pumps, DVD

Players

100 Watts

1.3 hours

Faxes, tVs, Small Power tools

150 Watts

50 Minutes

Computer Printer, Medium Power

tools, Blenders

200 Watts

40 Minutes

The maximum continuous load is 400 watts.
*note: Estimated run-times. Actual time may vary. Times are based on the internal

battery being fully charged.

PoWeRIng A 110V AC DeVICe

There are two-110 volt AC POWER outlets

located on the front panel.
To operate a 110 volt AC device:

1. Make sure the device to be powered

is OFF.

2. Plug the 110V AC device power cord

into a AC POWER outlet located on

the front panel. Push the INVERTER

switch located on left side of front

panel to ON (I). The digital display

will show 0.

3. Turn ON the 110V AC device. The

digital display will show the draw of

watts from device plugged in.

4. If a device will not operate properly

when first connected to the inverter,

push the INVERTER rocker switch

ON (I), OFF (0), and ON (I) again in

quick succession. If this procedure

is not successful, it is likely the PP-

18400CI inverter does not have the

required capacity to operate the

device(s) in question. Make sure the

wattage does not exceed 400.

5. Turn OFF (0) the INVERTER switch

when finished.

6. Charge the PP-18400CI as soon as

possible after each use.

CAUTION: Incorrect operation of your

inverter may result in damage and per-

sonal injury. Electrical current on a 110

volt circuit can be very dangerous.

tRoUBleShootIng the InVeRteR

1. Alarm sounds, and device plugged

in shuts off.

Continuous load demand or wattage

exceeds 400 watts. Push INVERTER

switch to the OFF (0) position.

Determine source of problem, and re-

solve it before reusing the inverter.

2. the Alarm Sounds.

Voltage from the internal battery

drops to approximately 10.5 volts.

When the power input drops to ap-

proximately 11 volts an alarm will

sound for an extended period.

3. Inverter shuts down.

The PP-18400CI inverter temperature

exceeds 145º F.

NOTE: The PP-18400CI is fitted with

a cooling fan that runs continuously

for loads drawing 25 watts or higher.

If cooling fan is unable to maintain

a cool enough temperature for safe

operation, inverter will automatically

shut down. If inverter automatically

shuts down or a continuous audible

alarm is heard, push INVERTER

switch to the OFF (0) position. Deter-

mine source of problem, and resolve

it before reusing the inverter.

This manual is related to the following products: