Attenzione, Warning, It gb – Smeg CW350RX1 User Manual
Page 16
363
IT
GB
5
NON COLLOCARE L’APPARECCHIO VICINO A SORGENTI DI CALORE E
LASCIARE ALMENO 5 CM DI ARIA SULLA PARTE SUPERIORE
Accostare l’apparecchio fino a che i distanzieri tocchino il muro.
Pulire le parti interne usando una soluzione di soda in acqua tiepida (1 cucchia-
io in 2 litri di acqua).
Non usare mai abrasivi e detersivi di alcun genere.
Attendere circa un’ora, prima di collocare la spina alla rete di alimentazione.
Equilibrare l’apparecchio per mezzo dei piedini anteriori regolabili.
ATTENZIONE:
1
2
3
4
WARNING:
5
DO NOT PLACE THE APPLIANCE NEAR HEAT SOURCES AND LEAVE AT
LEAST 5 CM OF SPACE ABOVE THE UPPER SECTION
Position the appliance so that the spacers touch the wall.
Clean the inside using a solution of sodium carbonate in warm water (1 tablespoon
in 2 litres of water). Never use abrasives or detergents of any kind.
Wait for approx. 1 hour before connecting to the mains.
Balance the appliance using the adjustable front feet.
1
2
3
4
COLLEGAMENTO ELETTRICO
Controllare che la tensione dell’impianto elettrico corrisponda a quella indicata
sulla targhetta caratteristiche posta sul lato sinistro in basso nella parte interna dello
scomparto frigorifero.
Se la presa a muro è priva di contatto a terra, o se la spina non è adatta al vostro
impianto vi consigliamo di rivolgervi ad un elettricista specializzato.
Non impiegare adattatori o derivatori che potrebbero causare riscaldamenti e bru-
ciature.
Green and Yellow
to Earth
Blue to
Neutral
13 amp
Fuse
Brown
to Live
Cord
Clamp
ELECTRICAL CONNECTION
Check that the main voltage corresponds to that indicated on the rating plate in the
lower left side inside the refrigerator compartment.
If the wall socket does not have an earth terminal, or if the plug does not fit into the
socket, it is advisable to consult a qualified electrician. Do not use multiple plugs or
adapters as they could cause heating and burning.
Warning: this appliance must be earthed
If this appliance is fitted with a non rewirable plug for which your socket is unsuitable,
the plug should be cut off and an appropriate plug fitted. The removed plug must be
disposed of Insertion of the plug into a 13 Amp socket is likely to cause an electrical
hazard When a nonrewirable plug ora rewirable 13 Amp (BS1363) plug is used it must
be fitted with a 13 Amp ASTA approved (BS1362) fuse. If any other type of plug is used
it must be protected by a 15 Amp fuse either in the plug or at the distribution board
Important:
The wires in the main leads are coloured in accordance with the following code:
GREEN AND YELLOW - EARTH BLUE - NEUTRAL
BROWN - LIVE
As the colours of the wires in the main lead of your appliance may not correspond
with the coloured marking identifying the terminals in your plug, proceed as follows.
CONNECT GREEN & YELLOW coloured wire to plug terminal marked letter “E” or
earth symbol or coloured green or green & yellow.
CONNECT BLUE coloured wire to plug terminal marked letter “N” or coloured black.
CONNECT BROWN coloured wire to plug terminal marked letter “L“ or coloured red.