beautypg.com

Trouble shooting, Table 1 – Shoprider ISO9001 User Manual

Page 25

background image

~24~

GMP

ISO9001

ISO14001

ISO13485

CERTIFIED



The Self-Help Guide (Table 1) is intended to assist in the location of a fault that
may occur in a certain part of the Powerchair.

If after checking out the fault from the table below and the fault is still
showing, do not use the Powerchair. Turn off the power and consult your
provider immediately.

Table 1

BATTERY GAUGE

POSSIBLE FAULT

10 Bars flash

Battery voltage is too high. Check the battery connections.

9 Bars flash

Solenoid brake fault. Check free wheel levers.

8 Bars flash

Possible joystick controller fault.

7 Bars flash

Possible joystick fault.

6 Bars flash

Battery charger connected.

5 Bars flash

Right-hand motor wiring fault.

4 Bars flash

Right-hand motor disconnected.

3 Bars flash

Left-hand motor wiring fault.

2 Bars flash

Left-hand motor disconnected.

1 Bar flashes

Low battery voltage.

TROUBLE SHOOTING