LIGHTING INSTRUCTIONS

1. Stop! Read the safety information above.

2. Make sure manual shut-off valve is fully open.

3. Locate gas control knob and piezo.

4. Depress control knob in and turn clockwise to the

“OFF” position (

Figure 18 ).

5. Wait 5 minutes to clear out any gas. Then smell for gas,

including near the floor. If you smell gas, STOP! Follow “B” in
the safety information above. If you do not smell gas, go to the
next step.

6. The pilot is located on the right side in front of the burner

(

Figure 19 ).

7. Depress control knob in and turn counterclockwise

to the “PILOT” position (

Figure 20 ). Press the control knob all

the way in for 5 seconds.

Note: If you are running the heater for the first time it will be
necessary to press the control knob all the way in for 30
seconds to allow air to bleed out of the gas piping.

MANUAL MATCH LIGHTING PROCEDURE — EMERGENCY ONLY

1. If the pilot cannot be lit with the piezo igniter, the heater can be

manually lit with a match.

2. With the right hand, depress and turn the control knob

counterclockwise to the “ON” position. Hold in the
knob.

TO TURN OFF GAS TO HEATER

1. Depress and turn control knob clockwise to the “OFF”

position (

Figure 18 ).

3. Light the match and hold the flame to the end of the pilot and

ignite the pilot.

4. Continue to hold control knob for an additional 10 seconds to

insure pilot remains lit.

5. Release the control while turning control knob to desired

setting.

8. With the control knob pressed in, push in and release the

piezo igniter button to light the pilot.

9. Hold the control knob in for a further 10 seconds to prevent

the flame failure detector from shutting off the gas while the
probe is warming up.

10. Release the control knob while turning counterclockwise

to the "ON" Position (

Figure 21 ). Then adjust

"HI-LO" knob to prefered setting.

If the knob does not pop out when released, stop and
immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, depress and
turn the gas control knob clockwise to “OFF”
and wait 30 seconds. Depress and turn knob counter-
clockwise to “ON” and press igniter button
again. If your pilot does not relight depress and turn
control knob clockwise to “OFF” and call your
service technician or gas supplier.

11. Wait 30 seconds before readjusting the heater when the

control knob has been turned down to a lower setting.

Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to push in or turn the gas control knob.

Never use tools. If the knob will not push in or turn by hand, do
not try to repair it, call a qualified service technician. Forced or
attempted repair may result in a fire or explosion.

D. Do not use this heater if any part has been under water.

Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.

A. This heater has a pilot which must be lit by hand. When

lighting the pilot, follow these instructions exactly.

B. BEFORE OPERATING smell all around the heater area for gas.

Be sure to smell next to the floor because some gas is heavier
than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone

in your building.

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY