beautypg.com

Installation – Sharp AF-06ERL User Manual

Page 6

background image

6

Insert the right closure assembly and the
left closure assembly into the top angle
and the bottom channels.
Secure the right and left closure to the
cabinet with six of the provided screws.
(L=

13

/

32

", 10mm)

2

3

Open the window sash and place the air
conditioner on the sill.

Balance the unit on the sill and close the
window sash securely behind the top
angle.

4

Insert the bottom gasket into the space
between the window sill and the bottom of
the unit to seal outside air.

If there is space between the bottom
channel and the sill, fill the gap with a thin
board or other hard filler.

INSTALLATION INSTRUCTIONS

Closure assembly

Bottom gasket

Cut the window sash foam seal (adhesive
type) to the proper length and attach it to
the underside of the window sash.

1

WARNING: Make sure the unit is turned off and unplugged before working.

Sash

Jamb

Sill

Window sash foam seal
(adhesive type)

WARNING:

unit

sill

incline backwards approximately
1cm (

3

/

8

")

At this step, make sure the unit is inclined
approximately 1 cm (

3

/

8

") to the back.

If the unit is not properly inclined, the water
collected in the bottom tray during opera-
tion will not drain properly and may flow into
the room where the air conditioner is in-
stalled.

INSTALLATION