Models, 10” flue riser, Casters-all swivel-front with locks – Southbend 400 series User Manual
Page 2: Auxillary griddle plates, Extra oven racks, Stainless steel rear panel, Cabinet base
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Models:
www.yatesgd.com www.yatesgraphicdesign.com
436D-1G/T
436A-1G/T
436D-2G/T
436A-2G/T
436D-3G/T
436A-3G/T
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE
.
OPTIONS AND ACCESSORIES
MISCELLANEOUS
UTILITY INFORMATION
GAS:
(436D-)
- Total BTU: NAT: 436D-1G -209,000; LP: 168,000 BTU
- Total BTU: NAT: 436D-2G/T-159,000; LP: 136,000 BTU
- Total BTU: NAT: 436D-3G/T-109,000; LP: 104,000 BTU
(436A-)
- Total BTU: NAT: 436A-1G -196,000; LP: 158,000 BTU
- Total BTU: NAT: 436A-2G/T -146,000; LP: 126,000 BTU
- Total BTU: NAT: 436A-3G/T -96,000; LP: 94,000 BTU
- One 3/4” female connection. See drawing above for location.
- Required minimum inlet pressure
- Natural gas 4” W.C.
- Propane gas 10” W.C.
ELECTRICAL:(436A ONLY)
- Standard -115/60/1 phase, furnished with 6’ cord with 3-prong
plug. Total max amps 4.8.
- Optional -208/230,50/60/1 or 3 phase. Supply must be wired
to junction box with terminal block located in rear. Total max
amps 2.6
Form 436D-1G,2G, 3G Rev 1 (04/07)
10” Flue Riser
3/4” quick disconnect with flexible hose complies with
ANSI Z 21.69 (specify 3ft, 4ft, 5ft)
Casters-all swivel-front with locks
Hot Top plates - each plate replaces 2 Open burner section
Various salamander & cheesemelter mounts
available. (Please refer to the price list)
Auxillary griddle plates
Extra Oven Racks
Stainless Steel rear panel
Cabinet Base
NOTES:
1. Optional -Hot Plate in lieu of 2
open top burners at 12,000 BTU/
burner (24,000 BTU total NAT or LP)
2. T Prefix - Thermostat griddle
control with 1 throttling-type
thermostat per burner. Temperature
range of 100
o
to 450
o
F
M
ODELS
E
XTERIOR
C
OOK
T
OP
D
OOR
O
PENING
O
VEN
B
OTTOM
3/4"
G
AS
C
ONN
.
E
LECTRIC
W
IDTH
A
D
EPTH
B
C
D
E
F
G
H
J
K
L
M
N
O
P
Q
R
436D-1G
436D-2G/T,3G/T
36.50"
(927)
34.00"
(864)
29.75"
(756)
31.00"
(787)
12.00"
(305)
2.75"
(70)
59.50"
(1511)
22.50"
(572)
31.00"
(787)
6.00"
(152)
37.00"
(940)
15.50"
(394)
13.00"
(330)
3.25"
(83)
30.25"
(768)
-
-
436A-1G
436A-2G/T,3G/T
36.50"
(927)
44.50"
(1130)
29.75"
(756)
31.00"
(787)
12.00"
(305)
2.75"
(70)
59.50"
(1511)
22.50"
(572)
31.00"
(787)
6.00"
(152)
37.00"
(940)
15.50"
(394)
13.00"
(330)
3.25"
(83)
30.25"
(768)
24.00"
(610)
6.00"
(152)
M
ODELS
B
URNERS
(BTU
E
ACH
NAT/LP)
O
VEN
I
NTERIOR
C
RATE
S
IZE
C
UBIC
V
OLUME
C
RATED
W
EIGHT
G
RIDDLE
O
PEN
O
VEN
W
IDTH
D
EPTH
H
EIGHT
W
IDTH
D
EPTH
H
EIGHT
436D-1G
2@(16K/16K)
4@(33K/24K)
1@(45K/40K)
26.00"
(660)
26.50"
(673)
14.00"
(356)
44.00"
(1118)
45.50"
(1158)
48.00"
(1219)
55.6 cu. ft
1.57 cu.m.
645 lbs.
292.6 kg.
436D-2G/2T
3@(16K/16K)
2@(33K/24K)
1@(45K/40K)
436D-3G/3T
4@(16K/16K)
-
1@(45K/40K)
436A-1G
2@(16K/16K)
4@(33K/24K)
1@(32K/30K)
26.00"
(660)
24.00"
(610)
14.00"
(356)
436A-2G/2T
3@(16K/16K)
2@(33K/24K)
1@(32K/30K)
436A-3G/3T
4@(16K/16K)
-
1@(32K/30K)
- If using Flex-Hose, the I.D. should not be smaller than 3/4”
and must comply with ANSI Z 21.69
- If casters are used with flex hose, a restraining device
should be used to eliminate undue strain on the flex hose
- For installation on combustible floors (with 6” high legs) and
adjacent to combustible walls, allow 6” clearance.
- Install under vented hood
- Check local codes for fire, installation and sanitary regulations.
NOTICE:
Southbend has a policy of continuous product research and
improvement. We reserve the right to change specifications and
product design without notice. Such revisions do not entitle the
buyer to corresponding changes, improvements, additions or
replacements for previously purchased equipment.