Format Track — 50h
The Format Track command formats the common solid-state memory array.
Table 50: Format Track — 50h
Register
D
7
D
6
D
5
D
4
D
3
D
2
D
1
D
0
Feature
X
Sector Count
Sector Count
Sector Number
Sector Number (LBA7-0)
Cylinder Low
Cylinder Low (LBA15-8)
Cylinder High
Cylinder High (LBA23-16)
Drive Head
1
LBA
1
Drive
Head Number (LBA27-24)
Command
50h