Wear-level - f5h, Wear-level — f5h, Table 79: wear-level — f5h – Silicon Image SiliconDrive CF SSD-C08G(I)-3150 User Manual
Page 101

ATA C
OMMAND
B
LOCK
AND
S
ET
D
ESCRIPTION
SSD-C
XXX
(I)-3150 D
ATA
S
HEET
S
ILICON
S
YSTEMS
P
ROPRIETARY
This document and the information contained within it is confidential and proprietary to SiliconSystems, Inc.
All unauthorized use and/or reproduction is prohibited.
3150C-10DSR
P
AGE
91
F
EBRUARY
2, 2009
Wear-Level — F5h
The Wear-Level command is supported as an NOP command for the
purposes of backward compatibility with the ANSI AT attachment standard.
This command sets the Sector Count register to 0x00h.
Table 79: Wear-Level — F5h
Register
D
7
D
6
D
5
D
4
D
3
D
2
D
1
D
0
Feature
X
Sector Count
Completion Status
Sector Number
X
Cylinder Low
X
Cylinder High
X
Drive Head
X
X
X
Drive
Flag
Command
F5h