beautypg.com

Sony KP-53SV75A User Manual

Page 4

background image

– 4 –

KP-43T75A/53SV75A

RM-Y906

RM-Y906

4.

Self-diagnosis screen displays

In cases of malfunctions where it is not possible to determine the symptom such as when the power goes off occasionally or when

the screen disappears occasionally, there is a screen display on whether the malfunction occurred or not in the past (and whether

the detection circuit operated or not) in order to allow confirmation.

Quickly press the remote command button in the following order from the standby state.

Self Check

2 : +B OCP 000

2 : +B OCP

000

3 : +B OVP

000

4 : V Stop

000

5 : AKB

000

6 : H Stop

000

7 : HV

000

8 : Audio

000

101 : WDT

000

000 the range of values for number of
operations is 000-255.
For 256 or higher there is no count up
and the number remains at 255.

Diagnosis

Results

÷

Self-diagnosis screen display

5.

Self-Diagnosis Screen Display

The results display is not automatically cleared. In case of repairs and after repairs, check the self-diagnosis screen and be sure

to return the results display to “ 0 ”.

If the results display is not returned to “ 0 ” it will not be possible to judge a new malfunction after completing repairs.

When ending the self-diagnosis screen completely, turn the power switch OFF on the remote commander or the main unit.

˘

Be aware that this differs from the method of

entering the service mode (volume + ).

DISPLAY b Channel 5 b VOL – b POWER

1. Power off (Set to the standby mode)

2. DISPLAY b Channel 5 b VOL + b POWER (Service Mode)

3. Channel 8 b ENTER (Test reset = Factory preset condition)

This manual is related to the following products: