beautypg.com

1 test for prominent discrete tones (pdts), 11 electromagnetic immunity, 12 warranty – Seagate BARRACUDA GREEN ST2000DL003 User Manual

Page 20: 13 agency certification, 1 safety certification, 2 electromagnetic compatibility, Test for prominent discrete tones (pdts), Electromagnetic immunity, Warranty, Agency certification 2.13.1

background image

20

Barracuda Green SATA Product Manual, Rev. B

Drive Specifications

www.seagate.com

2.10.1 Test for Prominent Discrete Tones (PDTs)

Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this
process is the use of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-
7) to discern tone audibility and to compensate for the inaudible components of sound prior to computation of
tone ratios according to Annex D of the ECMA-74 standards.

2.11 Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:

2.12 Warranty

To determine the warranty for a specific drive, use a web browser to access the following web page:

support.seagate.com/customer/warranty_validation.jsp

From this page, click on the “Verify Your Warranty” link. You will be asked to provide the drive serial number,
model number (or part number) and country of purchase. The system will display the warranty information for your
drive.

2.13 Agency certification

2.13.1 Safety certification

These products are certified to meet the requirements of UL60950-1, CSA60950-1 and EN60950 and so marked
as to the certify agency.

2.13.2 Electromagnetic compatibility

Hard drives that display the CE mark comply with the European Union (EU) requirements specified in the
Electromagnetic Compatibility Directive (2004/108/EC) as put into place 20 July 2007. Testing is performed to the
levels specified by the product standards for Information Technology Equipment (ITE). Emission levels are defined
by EN55022, Class B and the immunity levels are defined by EN55024.

Table 4 Radio frequency environments

Test

Description

Performance

Level

Reference
standard

Electrostatic
discharge

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN61000-4-2: 95

Radiated RF
immunity

80MHz to 1,000MHz, 3 V/m,
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @
200Hz

A

EN61000-4-3: 96
ENV 50204: 95

Electrical fast
transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN61000-4-4: 95

Surge
immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN61000-4-5: 95

Conducted RF
immunity

150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz
sine

A

EN61000-4-6: 97

Voltage dips,
interrupts

0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds

C
C
C
B

EN61000-4-11: 94

This manual is related to the following products: