beautypg.com

Schumacher PID-760 User Manual

Page 7

background image

7

TROUBLESHOOTING

PROBLEM: Alarm is On

Reason/Solution

1.

Display shows

SC

. Device has a short circuit or

demands too much surge power.

Cycle inverter power OFF and ON.

If problem persists, use a larger inverter or a smaller

device.

Remove defective device.

See warranty and call Customer Service 800-621-

5485 (Hours: 7 a.m. – 4:0 p.m. CST).

2.

Display shows

Lob

. 12 volt battery too low.

Recharge/replace low battery.

.

Display shows voltage In between 10.5 and 11.0

volts.

12 Volt battery is low.

Recharge/replace low battery.

Inverter will automatically shut off after battery volt-

age reaches 10.5 Volts.

4.

Display shows

Hib

. 12 volt voltage is too high.

If in a vehicle, repair/replace the alternator or charg-

ing system.

Use a properly sized and rated 12 Volt battery.

If input voltage returns to 15 Volts or less, the in-

verter will automatically restart.