Schumacher PID-760 User Manual
Page 6
![background image](/manuals/147444/6/background.png)
6
LED DISPLAy
The LED readouts identify the current status of the
PID-760.
vOLTAGE IN: Voltage of vehicle’s battery or Portable Power
jump starter/DC power source.
vOLTAGE OUT: Voltage supplied to device through AC
receptacle.
POWER OUT: Power or wattage supplied to device plugged
into the inverter.
An audio alarm will sound when the following codes dis-
play. To stop the alarm, press the ON/OFF LED Selector
button:
bAd
– Inverter is not functional.
See warranty and call
Customer Service 800-621-5485 (Hours: 7 a.m. – 4:0
p.m. CST)
.
Hib
– Vehicle’s battery voltage is more than 15.5 volts.
Inverter will automatically restart after the voltage drops
below 15.5 volts.
Hi p
– The continuous load demand from the device
exceeds 760 watts.
HoT
– Inverter is overheated and automatically turns off
for a period of 1 – minutes to cool. Make sure inverter is
well ventilated. It will automatically restart after it cools.
Lob
– Vehicle’s battery voltage is less than 10.5 volts.
SC
– Short circuit, power surge or overload in the
device.