Siemens MCM 1902 User Manual
Page 21
Color monitor MCM 1902
A26361-K527-Z100-2-5E19
English - 13
Degaussing the monitor (Degauss)
The monitor is degaussed every time you switch it on. When color shifts occur in the screen display
due to the influence of magnetic fields, the screen must be degaussed manually.
Ê
Call the
Degauss
setting window.
The
Degaussing..
. screen is displayed and the screen is degaussed.
The
Degauss
window reappears after a few seconds.
i
During degaussing a muffled noise is produced, the colors may change and the picture
may wobble. These effects are normal.
There is no malfunction.
Do not use the function more often than once every half hour, as otherwise the full effect
is not ensured.
Activating the factory settings (Recall)
There are factory settings for the picture position, picture sides (pincushion, trapezoid,
parallelogram), asymmetrical pincushion distortion, tilt distortion and moiré reduction.
Ê
Call the
Recall
setting window.
Ê
Press the
!
button for
YES
to activate the factory settings, or press the
"
button for
NO
to
retain your own settings.
If you have selected
YES
, all settings listed above will be reset to the factory settings. All other
settings will remain the same.
Setting menu position (Menu Position)
This function allows you to move the menu window on the screen.
Ê
Call the
Menu Position
setting window.
Ê
Press the
$
,
#
,
!
or
"
button to move the menu window on the screen.
Setting menu duration (Menu Duration)
With this function you can set how long the OSD menu is to be displayed each time (3, 7, 10, 20 or
50 seconds).
Ê
Call the
Menu Duration
setting window.
Ê
Press the
!
or
"
button to choose the duration (in seconds).
Correcting unsymmetrical pincushion distortion (Pinbalance)
Unsymmetrical pin balance is when the sides of the screen displays are bent inward or outward on
one side.
Ê
Call the
Pinbalance
setting window.
Ê
Press the
!
or
"
button to adjust the pinbalance setting.