Site preparation, Electrical requirements – Sub-Zero IC-27FI User Manual
Page 8

Site Preparation
8
Electrical Requirements
The electrical supply should be located within the shaded
area shown in the illustrations below. Follow the National
Electrical Code and local codes and ordinances when
installing the receptacle. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
IMPORTANT NOTE:
It is critical that the electrical outlet be
located within the shaded area shown so it does not inter-
fere with installation of the anti-tip bracket. It must be
flush with the back wall and positioned with the grounding
prong to the right of the thinner blades.
Electrical Requirements
Power Supply
115 V AC, 60 Hz
Circuit Breaker
15 amp
Receptacle
3-prong grounding-type
Do not use an extension cord or two-prong adapter.
Do not remove the power supply cord ground prong.
The outlet must be checked by a qualified electrician
to be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.