Specifications, Performance – Sanyo MDF-793AT User Manual
Page 28
27
SPECIFICATIONS
Name
Ultra-Low Temperature Freezer
Model
MDF-593/MDF-593AT MDF-793/MDF-793AT
External dimensions
W2010 x D770 x H1070 (mm)
W2570 x D770 x H1070 (mm)
Internal dimensions
W1280 x D500x H762 (mm)
W1840 x D500x H762 (mm)
Effective capacity
487 L
701 L
Exterior
Baked on acrylic finish on galvanized steel
Interior
Stainless steel
Door
Baked on acrylic finish on galvanized steel
Insulation
Rigid polyurethane foamed-in place
Compressor Hermetic
type
Motor for compressor
High stage side; 750 W
Low stage side; 750 W
High stage side; 1100 W
Low stage side; 1100 W
Condenser
High stage side; fin and tube type, Low stage side; shell and tube type
Evaporator
Tube on sheet type
Refrigerant
High stage side; R-407D , Low stage side; R-508 (TP5R3)
Power source
AC 200 V, 60 Hz
Temperature controller
Microprocessor control system, Setting range; -20 to -95
o
C, 1
o
C graduation
Temperature display
Digital display (+50 to -100
o
C)
Sensor
Pt 100
Alarm
Nickel-cadmium battery, Remote alarm contact, Buzzer and lamp
Battery
For power failure alarm; 6VDC, 270mAh
Voltage booster
Electrical; 208/230 V, 1 HP, 60 Hz
Minimum operating voltage; 193 V at start-up of compressor
Accessories
1 set of key, 2 rubber caps, 1 scraper
Weight
319 kg
380 kg
Option
Aluminum container; MDF-59SC, Inventory rack; IR213C, IR309C
Temperature recorder; MTR-85H, CVK-UB2
Note
Design or specifications will be subject to change without notice.
The battery for power failure alarm is an article for consumption. It is recommended that the battery
will be replaced about every 3 years. Contact Sanyo sales agency at the time of replacement of the
battery for recycling.
PERFORMANCE
Model MDF-593/MDF-593AT
MDF-793/MDF-793AT
Cooling performance
Center part of freezing room; -86
o
C (Ambient temperature; +30
o
C, no load)
Temperature Control range
-20 to -85
o
C
Power source
AC 200V, 60Hz
Rated power consumption
1100 W
1240 W
Noise level
61
dB [A] (background noise; 20 dB)
Maximum pressure
1.9 MPa
2.1 MPa
Note
The unit with CE mark complies with EC directives 89/336/EEC, 93/68/EEC and 73/23/EEC