SPECIFICATIONS

Name

Ultra-Low Temperature Freezer

Model

MDF-593/MDF-593AT MDF-793/MDF-793AT

External dimensions

W2010 x D770 x H1070 (mm)

W2570 x D770 x H1070 (mm)

Internal dimensions

W1280 x D500x H762 (mm)

W1840 x D500x H762 (mm)

Effective capacity

487 L

701 L

Exterior

Baked on acrylic finish on galvanized steel

Interior

Stainless steel

Door

Baked on acrylic finish on galvanized steel

Insulation

Rigid polyurethane foamed-in place

Compressor Hermetic

type

Motor for compressor

High stage side; 750 W

Low stage side; 750 W

High stage side; 1100 W

Low stage side; 1100 W

Condenser

High stage side; fin and tube type, Low stage side; shell and tube type

Evaporator

Tube on sheet type

Refrigerant

High stage side; R-407D , Low stage side; R-508 (TP5R3)

Power source

AC 200 V, 60 Hz

Temperature controller

Microprocessor control system, Setting range; -20 to -95

o

C, 1

o

C graduation

Temperature display

Digital display (+50 to -100

o

C)

Sensor

Pt 100

Alarm

Nickel-cadmium battery, Remote alarm contact, Buzzer and lamp

Battery

For power failure alarm; 6VDC, 270mAh

Voltage booster

Electrical; 208/230 V, 1 HP, 60 Hz

Minimum operating voltage; 193 V at start-up of compressor

Accessories

1 set of key, 2 rubber caps, 1 scraper

Weight

319 kg

380 kg

Option

Aluminum container; MDF-59SC, Inventory rack; IR213C, IR309C

Temperature recorder; MTR-85H, CVK-UB2

Note

Design or specifications will be subject to change without notice.

The battery for power failure alarm is an article for consumption. It is recommended that the battery

will be replaced about every 3 years. Contact Sanyo sales agency at the time of replacement of the

battery for recycling.

PERFORMANCE

Model MDF-593/MDF-593AT

MDF-793/MDF-793AT

Cooling performance

Center part of freezing room; -86

o

C (Ambient temperature; +30

o

C, no load)

Temperature Control range

-20 to -85

o

C

Power source

AC 200V, 60Hz

Rated power consumption

1100 W

1240 W

Noise level

61

dB [A] (background noise; 20 dB)

Maximum pressure

1.9 MPa

2.1 MPa

Note

The unit with CE mark complies with EC directives 89/336/EEC, 93/68/EEC and 73/23/EEC